8
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
ERROR CODE and TROUBLESHOOTING
8 - 85
[E870] RADF open jam
[E871] Cover open jam in the read ready status
[E890] ADF time out jam
Classification
Error item
RADF jam
RADF has opened during RADF operation.
Check item
Measures
RADF
• Close the RADF if it is opened.
• Remove if there is any original before closing it.
RADF opening/closing sensor
• Sensor check
(Perform the input check: 03: [FAX]/ON/[7]/[D])
• Connector check
• Harness check
RADF board
• Connector check (CN74)
• Board check
Replace parts
Remarks
RADF opening/closing sensor
RADF board
Perform the 05-3210
Classification
Error item
RADF jam
Jam caused by opening of the Original jam access cover or
front cover while the RADF is waiting for the scanning start
signal from the equipment.
Check item
Measures
RADF
• Close the RADF if it is opened.
• Remove if there is any original before closing it.
Original jam access cover opening/
closing sensor
• Sensor check
(Perform the input check: 03: [FAX]/ON/[7]/[C])
• Connector check
• Harness check
RADF board
• Connector check (CN74)
• Board check
Replace parts
Remarks
Original jam access cover opening/
closing sensor
RADF board
Perform the 05-3210
Classification
Error item
RADF jam
ADF time out jam
Check item
Measures
RADF
• Check if there is any paper in the RADF. Remove it if there
is.