Supplies and user maintenance
TONER CARTRIDGE REPLACEMENT
Remove the toner cartridge from the bag. Grasp the cartridge on both sides and
shake it horizontally four or five times. After shaking the cartridge, remove the
toner seal.
Grasp the toner cartridge as shown in the illustration. Do not hold the cartridge
by the shutter. Be sure to only shake the cartridge before the toner seal is
removed.
4 or 5 times
Shutter
Toner seal
Gently insert the toner cartridge along the guides until it locks in place while pushing
the lock release lever. Remove the tape from the shutter. Pull the shutter out of the
toner cartridge as shown in the illustration. Discard the shutter.
Close the front cover and then the side cover by pressing the round projections near
the side cover open button. The
indicator will go out and the ready (
) indicator
will light up.
When closing the covers, be sure to close the front cover securely and then
close the side cover. If the covers are closed in the wrong order, the covers may
be damaged.
Even after a new toner cartridge is installed, the ready (
) indicator may not
light up, indicating copying cannot be restarted (toner is not sufficiently fed). In
this case, open and close the side cover. The copier will feed toner again
approximately 2 minutes and then copying can be restarted.