EOI Remote Mounting
https://www.toshiba.com/tic/
25
EOI Remote Mounting
For safety and application-specific reasons, some
ASD installations will warrant that the operator not
be in the vicinity during operation or that the EOI
not be attached to the ASD housing. The EOI may
be mounted remotely either with or without the
optional Remote Mounting Kit (P/N ASD-MTG-
KITQ9) which allows for remote EOI placement and
easier cable routing.
The EOI can operate up to 9 feet away from the
ASD. An EOI extender cable is required for remote
mounting and is included with Remote Mounting Kit
or can be ordered through the Customer Support
Center.
Remote Mounting Hardware
• Remote Mounting Kit (optional) — P/N ASD-
MTG-KITQ9
• LCD Cable, 9 ft. — P/N 76268
Remote Mounting Installation Precautions
Install the unit securely in a well-ventilated area that
is out of direct sunlight. The ambient temperature
rating for the display module is 14° to 104° F (-10°
to 40° C).
• Select a mounting location that is easily
accessible by the user.
• Avoid installation in areas where vibration, heat,
humidity, dust, metal particles, or high levels or
electrical noise (EMI) are present.
• Do not install the unit where it may be exposed to
flammable chemicals or gases, water, solvents, or
other fluids.
• Turn on the power only after securing the front
cover of the ASD.
Remote Mounting Using the Mounting Kit
Note:
See
dimensions and the item locations
referenced in steps 1 – 7.
1. At the EOI mounting location, mark the 4.60” by
4.50” hole and the four 11/32” screw holes.
2. Cut the 4.60” by 4.50” rectangular mounting hole.
3. Drill the four 11/32” screw holes for the Bezel
Plate mount.
4. Attach and secure the Bezel Plate to the front
side of the mounting location using the four 10-32
hex nuts, #10 split lock washers, and the #10 flat
washers.
5. Remove the Front Panel Assembly of the ASD —
using a flathead screwdriver, release the upper
retaining tabs of the EOI panel then pivot the EOI
assembly away from the ASD and lift
(see
).
6. Remove the Display Module from the Front Panel
Assembly of step 5 — discard the assembly.
7. Attach and secure the Display Module to the front
side of the Bezel Plate using the four 6-32 x
5/16” pan head screws, and the #6 split lock
washers.
When installing the Display Module into the Bezel
Plate ensure that the left side of the display is
inserted first with the top and bottom catches
securely in place (adjacent to the Phillips screws at
underside of display). This ensures the proper
alignment and electrical connection of the CNX
connector of the Display Module PCB. Then gently
hold the display in place while securing the Phillips
mounting screw.
8. Install the Front Panel Connector Assembly to
).
9. Connect the Extender Cable from the EOI to the
Front Panel Assembly.
Summary of Contents for DN-68249-003
Page 1: ...ADJUSTABLE SPEED DRIVES Q9 DN 68249 003 INSTALLATION OPERATION MANUAL April 2020 ...
Page 2: ......
Page 3: ...Document Number 68249 003 April 2020 Q9 Plus ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...Table of Contents Q9 Plus ASD Install Op Manual iv https www toshiba com tic ...
Page 305: ......