Direct Access Parameter Information
Input Terminal 1 (F) Response Time
Program
Terminal
Input Terminal Delays
This parameter delays the response of the ASD to any change in
the F terminal input by the programmed value.
The delay may be increased to provide additional electrical noise
immunity or to prevent the ASD from responding to contact
bounce or chatter.
Direct Access Number —
F140
Parameter Type —
Numerical
Factory Default —
8
Changeable During Run —
No
Minimum — 2
Maximum — 200
Units — mS
Input Terminal 2 (R) Response Time
Program
Terminal
Input Terminal Delays
This parameter delays the response of the ASD to any change in
the R terminal input by the programmed value (see waveforms at
).
The delay may be increased to provide additional electrical noise
immunity or to prevent the ASD from responding to contact
bounce or chatter.
Direct Access Number —
F141
Parameter Type —
Numerical
Factory Default —
8
Changeable During Run —
No
Minimum — 2
Maximum — 200
Units — mS
Input Terminal 4 (RES) Response Time
Program
Terminal
Input Terminal Delays
This parameter delays the response of the ASD to any change in
the RES terminal input by the programmed value (see wave
-
).
The delay may be increased to provide additional electrical noise
immunity or to prevent the ASD from responding to contact
bounce or chatter.
Direct Access Number —
F143
Parameter Type —
Numerical
Factory Default —
8
Changeable During Run —
No
Minimum — 2
Maximum — 200
Units — mS
Input Terminal 5 – 12 Response Time
Program
Terminal
Input Terminal Delays
This parameter delays the response of the ASD to any change in
the 5 – 12
terminal inputs by the programmed value (see wave
-
).
The delay may be increased to provide additional electrical noise
immunity or to prevent the ASD from responding to contact
bounce or chatter.
Direct Access Number —
F144
Parameter Type —
Numerical
Factory Default —
8
Changeable During Run —
No
Minimum — 2
Maximum — 200
Units — mS
Summary of Contents for DN-68249-003
Page 1: ...ADJUSTABLE SPEED DRIVES Q9 DN 68249 003 INSTALLATION OPERATION MANUAL April 2020 ...
Page 2: ......
Page 3: ...Document Number 68249 003 April 2020 Q9 Plus ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...Table of Contents Q9 Plus ASD Install Op Manual iv https www toshiba com tic ...
Page 305: ......