3
This specification subjects to change without notice.
D4134992A
Phase difference:
The phase difference between the trailing edge
of VD and the trailing edge of HD must be as
shown below.
Output signal:
HD,VD negative polarity
Level:
3.5 to 4.5V(p-p) / 1k ohm terminated
8.0 to 9.0V(p-p) / high
Pulse width:
HD:
6.36±0.5 micro sec
VD:
572±5 micro sec
Repeat frequency:
f
H
=15.73426 kHz
f
v
=2 f
H
/525
Scanning lines:
525 lines
Output circuit:
Electronic line display or reticle (CS3330BLi ONLY)
NO. of lines:
2 horizontal lines, 2 vertical lines
Movable range:
Entire monitor screen
Line width:
Horizontal line: 1 scanning line/field
Vertical line:
approx. 0.5 micro sec
Polarity :
White(POSI) / black(NEGA) selectable
ON/OFF:
switching
Electronic line / reticle:
Internal selector switch
(Factory preset is electronic line.)
Gamma:
0.45/1 selectable
AGC:
ON/OFF switching
2
nd
field
t
2
=1/f
H
/2 +/-5 micro sec
t
1
=
0+/-5 micro sec
1
st
field
VD
HD
TD62504F
HD
VD
1k
ohm
+9V