- 5 -
TO REMOVE CRT (Same procedure for R, G, B)
1. Remove CRT DRIVE Board, S. V. M. COIL and
DEF. YOKE from CRT.
2. Remove Lens Assembly.
3. Detach CRT Anode Cap from CRT.
4. Remove CRT Assembly from CRT Mounting.
CRT REPLACEMENT (Same procedure for R, G, B)
Reverse the removal procedures except the followings.
1. Anode Cable should be replaced with new one.
See “SERVICING PRECAUTIONS” shown below.
2. Install silicon (T461B) to the CRT, replace the Anode
cable and put enough silicon again on around the An-
ode Cap as illustrated.
CAUTION: Align the Anode cable as illustrated on page
4.
ADJUSTING PROCEDURE IN REPLACING CRT
1. R.G.B. FOCUS ADJUSTMENT (page 7.)
2. PICTURE TILT ADJUSTMENT (page 7.)
3. USER CONVERGENCE CENTER CHECK
(See owner's manual.)
4. CENTERING ADJUSTMENT (page 7.)
5. CONVERGENCE ADJUSTMENT (page 15.)
6. WHITE BALANCE ADJUSTMENT (page 12.)
Adjustments are complete.
SERVICING PRECAUTIONS
Check the point of anode lead in a straight
line, if it is winding, please revise it.
Anode lead holder
Do not use a magnetized screw driver for screws
of Deflection Yoke and Velocity Modulation Coil to
avoid magnetization of electron gun.
Magnetization of electron gun will degrade basic
function and result in unbalance of right and left
shift of user static convergence, and result in no
variable quantity.
When replacing the anode cap assembly (CRT) or
anode lead assembly (F.B.T.), remove the anode
lead holder from old one and attach the holder
again to new anode lead.
Anode Cap
Silicon
(On shaded area)
TSE3843W #23960136
2 ~ 5 mm
15 ~ 25 mm
Screw for
D.Y
Screw for SVM coil
Summary of Contents for 57H84 - 57" Rear Projection TV
Page 8: ... 8 LOCATION OF SCREEN AND FOCUS VR S FOCUS COVER Speaker grille G B R SCREEN ...
Page 35: ...SCAN CONVERTER MODUL MHSU11 PD1738 U001 BOTTOM FOIL SIDE 36 37 ...
Page 36: ...SCAN CONVERTER MODUL MHSU11 PD1738 U001 TOP COMPONENT SIDE 38 39 ...
Page 45: ... 53 54 CIRCUIT BLOCK DIAGRAM ...
Page 47: ......