- 26 -
CIRCUIT CHECKS
HIGH VOLTAGE CHECK
CAUTION:
There is no HIGH VOLTAGE ADJUSTMENT on this chassis. Checking should be done following the steps below.
1. Connect an accurate high voltage meter to the anode of the picture tube.
2. Turn on the receiver. Set the BRIGHTNESS and CONTRAST to minimum (zero beam current).
3. High voltage must be measured below (B) kV.
Refer to table-1 for high voltage (B).
(See SETTING & ADJUSTING DATA on page 27)
4. Vary the BRIGHTNESS to both extremes to be sure the high voltage does not exceed the limit under any conditions.
CAUTION:
When the following parts fail, check the High Voltage after replacing.
ANODE VOLTAGE MEASURING METHOD
CAUTION: Take extra precaution when measuring this high voltage. High voltages are also present in surrounding circuit
boards (CRT DRIVE assembly, DEFLECTION assembly, and POWER SUPPLY assembly).
1. Disconnect the FBT anode cable as outlined below. Measure high voltage at the point where the cable enters the FBT.
2. Holding the rubber cover firmly, turn it counterclockwise and check that the lock has been disengaged. (See Fig. b on page
8.)
3. Determine the extent of the rubber cover before disconnecting the cable.
4. Pull straight up the anode cable to disconnect.
5. When reconnecting the cable, proceed in the reverse order.
After reconnecting, tug on the cable to check that it is secure.
Location
No.
Name
Name
T461
C440
C443
C444
C467
C468
Flyback Trans.
Capacitor
Capacitor
Capacitor
Capacitor
Capacitor
TFB3091AD
1500pF,
±
3%
4700pF,
±
3%
3600pF,
±
3%
12000pF,
±
5%
12000pF,
±
5%
Summary of Contents for 43VJ33Q
Page 28: ... 28 LOCATION OF CONTROLS Power Button RED Power On Power Button RED Power On 43VJ33Q 50VJ33Q ...
Page 31: ... 31 K502 K501 Labels K601 A004 A420 A201 K101 K102 K103 A424 A225 A258 MECHANICAL DISASSEMBLY ...
Page 45: ... 46 45 SIGNAL BOARD PD0817E U902 BOTTOM FOIL SIDE ...
Page 46: ... 48 47 DEF CONV BOARD PD0818B U904 BOTTOM FOIL SIDE ...
Page 47: ... 50 49 POWER BOARD PD0819B U903 BOTTOM FOIL SIDE ...
Page 54: ......