– 26 –
CIRCUIT CHECKS
HIGH VOLTAGE CHECK
CAUTION: There is no HIGH VOLTAGE ADJUSTMENT on this chassis. Checking should be done following the steps below.
1. Connect an accurate high voltage meter to the anode of the picture tube.
2. Turn on the receiver. Set the BRIGHTNESS and CONTRAST to minimum (zero beam current).
3. High voltage must be measured below (B) kV.
Refer to table-1 for high voltage (B).
(See SETTING & ADJUSTING DATA on page 27)
4. Vary the BRIGHTNESS to both extremes to be sure the high voltage does not exceed the limit under any conditions.
CAUTION:
When the following parts fail, check the High Voltage after replacing.
ANODE VOLTAGE MEASURING METHOD
CAUTION: Take extra precaution when measuring this high voltage. High voltages are also present in surrounding circuit
boards (CRT DRIVE assembly, DEFLECTION assembly, and POWER SUPPLY assembly).
1. Disconnect the FBT anode cable as outlined below. Measure high voltage at the point where the cable enters the FBT.
2. Holding the rubber cover firmly, turn it counterclockwise and check that the lock has been disengaged. (See Fig. b on page
8.)
3. Determine the extent of the rubber cover before disconnecting the cable.
4. Pull straight up the anode cable to disconnect.
5. When reconnecting the cable, proceed in the reverse order.
After reconnecting, tug on the cable to check that it is secure.
Location
No.
Name
Name
T461
Z
C443
C444
C467
C468
Flyback Trans.
Capacitor
Capacitor
Capacitor
Capacitor
TFB3094
YZ
4700pF, ±3%
4700pF, ±3%
100
00pF, ±3%
82
00pF, ±3%
GENERAL ADJUSTMENTS
Summary of Contents for 43CJH9UR
Page 45: ...HYPER SIGNAL BOARD UD1828 U901 TOP COMPONENT SIDE 47 48 ...
Page 46: ...HYPER SIGNAL BOARD UD1828 U901 BOTTOM FOIL SIDE 49 50 ...
Page 51: ...SPECIFIC INFORMATIONS TERMINAL VIEW OF TRANSISTORS 59 ...
Page 52: ... 60 MEMO SPECIFIC INFORMATIONS ...
Page 56: ... 64 MEMO SPECIFIC INFORMATIONS ...
Page 58: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...