Vinyl tape
Apply after carrying
out a drainage test.
600 mm or more only
when unobstructed
to the front and both
sides.
Extension
drain hose
(Not available,
provided by installer)
100 mm or more
100 mm or more
600 mm or more
600 mm or more
600 mm or more
Saddle
1
Installation plate
50 mm or more
50 mm or more
Shield pipe
Air fi lter
70 mm or more
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
Part
code
Parts name
Q’ty
A
Refrigerant piping
Liquid side :
∅
6.35 mm
Gas side
:
∅
9.52 mm
One
each
B
Pipe insulating material
(polyethylene foam, 8 mm thick)
1
C
Putty, PVC tapes
One
each
Optional Installation Parts
•
Secure the outdoor unit with fi xing bolts and nuts if the unit is likely to be exposed
to a strong wind.
•
Use
∅
8 mm or
∅
10 mm anchor bolts and nuts.
•
If it is necessary to drain the defrost water, attach drain nipple and cap water proof
to the bottom plate of the outdoor unit before installing it.
Fixing bolt arrangement of outdoor unit
RAS-25, 35S3AVP-ND
3
Batteries
6
Flat head
wood screw
4
Remote control holder
Remark :
•
Detail of accessory and installation
parts can see in the accessory sheet.
When installing the outdoor unit,
leave open in at least two of direction
(A), (B), (C) and (D) shown in the
fi gure on the right.
Do not allow the drain hose to get
slack.
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected to the left, rear left, rear
right, right, bottom right or bottom
left.
Insulate the refrigerant pipes
separately with insulation, not
together.
8 mm thick heat resisting
polyethylene foam
Cut the piping
hole sloped
slightly.
Right
Rear right
Left
Bottom right
Rear left
Bottom left
Cut dot-line area
In case of right or left piping
* Drain nipple and cap
water proof are packed
in outdoor unit.
X
When using a multi-system outdoor unit is used, refer to the installation manual
provided with the model concerned.
Air outlet
Drain outlet
Air inlet
108 mm
600 mm
28 mm
25 mm
90 mm
125 mm
320 mm
86 mm
102 mm
CAUTION
Install in rooms that are 13 m
3
or larger.
If a leak of refrigerator gas occurs
inside the room, an oxygen defi ciency
can occur.
5
Mounting screw
7
Insulation sheet
2
Wireless remote control
EN
SV
FI
NO
3