Toshiba 22SAV Installation Manual Download Page 10

8

OTHERS

OTHERS

Gas Leak Test

Test Operation

To switch the TEST RUN (COOL) mode, press RESET button for 10 seconds. 
(The beeper will make a short beep.)

Auto Restart Setting

The product was shipped with Auto Restart function in the off position. 
Turn it on as required.

     

How to set the Auto Restart

RESET

Hi POWER  FILTER         PAP         TIMER    OPERATION

Remote Control A-B Selection

PRESET

FAN

“B” Display

“00” Display

To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed near.

Remote Control B Setup.

1.  Press RESET button on the indoor unit to turn the air conditioner ON.
2.  Point the remote control at the indoor unit.
3.  Push and hold 

CHK 

 button on the Remote Control by the tip of the pencil. 

“00” will be shown on the display.

4. Press 

MODE

 during pushing 

CHK 

. “B” will show on the display and “00” will 

disappear and the air conditioner will turn OFF. The Remote Control B is 
memorized.

Note :  1.  Repeat above step to reset Remote Control to be A.
 

 

2.  Remote Control A have not “A” display.

 

 

3.  Default setting of Remote Control from factory is A.

•  When two indoor units are installed in the same room or adjacent two 

rooms, if operating a unit, two units may receive the remote control signal 
simultaneously and operate. In this case, the operation can be preserved 
by setting either one remote control to B setting. (Both are set to A setting 
in factory shipment.)

•  The remote control signal is not received when the settings of indoor unit 

and remote control are different.

•  There is no relation between A setting/B setting and A room/B room when 

connecting the piping and cables.

• Check the 

fl

 are nut connections 

for the gas leak with a gas leak 
detector or soap water.

This product is designed so that, after a power failure, it can restart 
automatically in the same operating mode as before the power failure.

1.  Press and hold the RESET button on the indoor unit for 3 seconds to set 

the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 
5 seconds)

2.  Press and hold the RESET button on the indoor unit for 3 seconds to 

cancel the operation. (3 beep sound but OPERATION lamp does not 
blink)

 

•  In case of ON timer or OFF timer are set, AUTO RESTART 

OPERATION does not activate.

RESET button

     

Stripping length of the connecting cable

Model

RAS-18SKV(R)

RAS-22SKV(R)

Power source

220 – 240 V Single phase, 50Hz
220 – 230 V Single phase, 60Hz

Maximum running current

12A

13.5A

Plug socket & fuse rating

16A

Power cord

H07RN-F or 60245 IEC66 (1.5 mm

2

 or more)

 

NOTE

       

: Connecting cable

•  Wire type : H07RN-F or 60245 IEC66 (1.0 mm

2

 or more)

•  Wrong wiring connection may cause some electrical parts burn out.
•  Be sure to comply with local rule on running the wire from indoor unit 

to outdoor unit (size of wire and wiring method, etc.).

•  Every wire must be connected 

fi

 rmly.

•  If incorrect or incomplete wiring is carried out, it will cause an ignition 

or smoke.

•  Prepare the power supply for exclusive use with the air conditioner.
•  This product can be connected to the mains.
 Connection 

to 

fi

 xed wiring: A switch which disconnects all poles and 

has a contact separation of at least 3 mm must be incorporated in the 

fi

 xed wiring.

CAUTION

Check places for
the indoor unit.

Electric parts 
cover

Check places for
the outdoor unit.

Valve cover

Information

10

10

10

10

30

30

40

40

L N

1 2 3

Connecting 
cable

Power cord

Terminal 
block

Earth line

Earth line

Connecting 
cable

Power cord

1110651154-EN.indd   8

1110651154-EN.indd   8

2/15/10   9:39:42 AM

2/15/10   9:39:42 AM

Summary of Contents for 22SAV

Page 1: ...r unit RAS 18 22SKV R Series Outdoor unit RAS 18 22SAV Series AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL 1110651154 Cover 1110651154 indd 1 Cover 1110651154 indd 1 1 22 10 11 14 26 AM 1 22 10 11 14 26 AM ...

Page 2: ...Installation 5 n Indoor Unit Fixing 6 n Drainage 6 OUTDOOR UNIT 6 n Installation Place 6 n Precautions about Installation in Regions with Snowfall and Cold Temperatures 6 n Refrigerant Piping Connection 7 n Evacuating 7 n Wiring Connection 7 n Electrical Work 7 OTHERS 8 n Gas Leak Test 8 n Remote Control A B Selection 8 n Test Operation 8 n Auto Restart Setting 8 Cover 1110651154 indd 2 Cover 1110...

Page 3: ...ing in damage to the unit or injury Do not modify the power cable connect the cable midway or use a multiple outlet extension cable Doing so may cause contact failure insulation failure or excess current resulting in fire or electrical shock If you detect any damage do not install the unit Contact your supplying dealer immediately New refrigerant air conditioner installation CAUTION THIS AIR CONDI...

Page 4: ...use electrical shock Follow the instructions in this installation manual to arrange the drain pipe for proper drainage from the unit Ensure that drained water is discharged Improper drainage can result in water leakage causing water damage to furniture Tighten the flare nut with a torque wrench using the prescribed method Do not apply excess torque Otherwise the nut may crack after a long period o...

Page 5: ...rain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 8 mm thick heat resisting polyethylene foam 1 Batteries Pan head wood screw Remote control holder Vinyl tape Apply after carrying out a drainage test Wireless remote control Saddl...

Page 6: ...he pipe hole dia 65 mm at a slight downward slant to the outdoor side A place which provides the spaces around the indoor unit as shown in the diagram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed as top of the indoor uni...

Page 7: ...pipe make sure to use a spring bender so as not to crush the pipe Bend the connecting pipe within a radius of 30 mm To connect the pipe after installation of the unit figure How to install the air inlet grille on the indoor unit When attaching the air inlet grille perform the same process as for removal but in reverse order Wiring Connection Wiring of the connecting cable can be carried out withou...

Page 8: ...cause any problems CAUTION 1 Install the outdoor unit in a location where there are no obstructions near its air intake or air outlet 2 When the outdoor unit is installed in a place that is always exposed to strong winds like on the coast or on a high story of a building secure the normal fan operation using a duct or a wind shield 3 Especially in windy areas install the unit to prevent the admiss...

Page 9: ...uid side Service port Valve core Setting pin Packed valve at gas side Vacuum pump Vacuum pump adapter for counter flow prevention For R410A only Charge hose For R410A only Handle Hi Keep full closed Manifold valve Pressure gauge Compound pressure gauge Handle Lo Charge hose For R410A only Connecting pipe 101 kPa 76 cmHg Open the valve stem until it touches the stopper Once it is in contact with th...

Page 10: ...ns for the gas leak with a gas leak detector or soap water This product is designed so that after a power failure it can restart automatically in the same operating mode as before the power failure 1 Press and hold the RESET button on the indoor unit for 3 seconds to set the operation 3 beep sound and OPERATION lamp blink 5 time sec for 5 seconds 2 Press and hold the RESET button on the indoor uni...

Page 11: ...Cover back 1110651154 indd 1 Cover back 1110651154 indd 1 1 22 10 11 15 21 AM 1 22 10 11 15 21 AM ...

Page 12: ...Cover back 1110651154 indd 2 Cover back 1110651154 indd 2 1 22 10 11 15 22 AM 1 22 10 11 15 22 AM ...