8
OTHERS
OTHERS
Gas Leak Test
Test Operation
To switch the TEST RUN (COOL) mode, press RESET button for 10 seconds.
(The beeper will make a short beep.)
Auto Restart Setting
The product was shipped with Auto Restart function in the off position.
Turn it on as required.
How to set the Auto Restart
RESET
Hi POWER FILTER PAP TIMER OPERATION
Remote Control A-B Selection
PRESET
FAN
“B” Display
“00” Display
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed near.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
CHK
button on the Remote Control by the tip of the pencil.
“00” will be shown on the display.
4. Press
MODE
during pushing
CHK
. “B” will show on the display and “00” will
disappear and the air conditioner will turn OFF. The Remote Control B is
memorized.
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A have not “A” display.
3. Default setting of Remote Control from factory is A.
• When two indoor units are installed in the same room or adjacent two
rooms, if operating a unit, two units may receive the remote control signal
simultaneously and operate. In this case, the operation can be preserved
by setting either one remote control to B setting. (Both are set to A setting
in factory shipment.)
• The remote control signal is not received when the settings of indoor unit
and remote control are different.
• There is no relation between A setting/B setting and A room/B room when
connecting the piping and cables.
• Check the
fl
are nut connections
for the gas leak with a gas leak
detector or soap water.
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
1. Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
• In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
RESET button
Stripping length of the connecting cable
Model
RAS-18SKV(R)
RAS-22SKV(R)
Power source
220 – 240 V Single phase, 50Hz
220 – 230 V Single phase, 60Hz
Maximum running current
12A
13.5A
Plug socket & fuse rating
16A
Power cord
H07RN-F or 60245 IEC66 (1.5 mm
2
or more)
NOTE
: Connecting cable
• Wire type : H07RN-F or 60245 IEC66 (1.0 mm
2
or more)
• Wrong wiring connection may cause some electrical parts burn out.
• Be sure to comply with local rule on running the wire from indoor unit
to outdoor unit (size of wire and wiring method, etc.).
• Every wire must be connected
fi
rmly.
• If incorrect or incomplete wiring is carried out, it will cause an ignition
or smoke.
• Prepare the power supply for exclusive use with the air conditioner.
• This product can be connected to the mains.
Connection
to
fi
xed wiring: A switch which disconnects all poles and
has a contact separation of at least 3 mm must be incorporated in the
fi
xed wiring.
CAUTION
Check places for
the indoor unit.
Electric parts
cover
Check places for
the outdoor unit.
Valve cover
Information
10
10
10
10
30
30
40
40
L N
1 2 3
Connecting
cable
Power cord
Terminal
block
Earth line
Earth line
Connecting
cable
Power cord
1110651154-EN.indd 8
1110651154-EN.indd 8
2/15/10 9:39:42 AM
2/15/10 9:39:42 AM