- 9 -
6. SELF DIAGNOSTIC FUNCTION
1) Press the "9" button on the Remote Controller while the
setting menu is displayed in the service mode.
The diagnosis will begin to check if the interface between
the IC's has been executed properly.
2) The following displays are shown on the screen during
the diagnosis.
Item
POWER
BLOCK
UV V1 V2
Result
Up to 255 times
Color classification
Green: Normal blocks
White: Non-diagnostic blocks
Red: Inspection requiring blocks
Description
Displays an abbreviated protection signal (the last circuit used) and
the number of detections.
Performs a diagnosis when a synchronization signal is detected from
the input or AUDIO/VIDEO signal is found to be present or absent. The
faulty location is displayed in color.
Execute a one-time diagnosis for the first time by pressing the 9 button
on the Remote Controller.
(1) Part number of microprocessor (QA51)
(4) RESIZE :
D
isplays th
e
resize firmware version.
(2) If all is well, the protecting circuit should display "00."
When the circuit displays another number, over current
is apt to flow, posing a risk of damage to the circuit parts.
(3) BLOCK
UV: TV reception mode
V1: VIDEO input mode (
1)
V2: VIDEO input mode (
2)
S
<SELF CHECK>
23 . . . . .
. . . . .
POWER : 00
BLOCK : UV V1 V2
(1)
(2)
(3)
RESIZE : 04
(4)