5
14AR22
CIRCUIT PROTECTION
The receiver is protected by a 3.15A fuse (F701),
mounted on PWB-A, wired into one side of the AC
line input.
+B DC REGULATOR CONFIRMATION
The + B DC output voltage adjustment is not included
in this circuit.However, should confirmation be
reguired proceed as follows.
1. Actuate receiver with 220V AC input voltage.
2. Receive a local channel.
3. Connect positive lead of digital voltmeter to C754
positive side on PWB-A ; negative lead to chassis
ground.
4. Confirm this voltage reading is as below.
CAUTION: The reading should be within 130
±
2.0V DC
to ensure normal function and circuitry
reliability.
X-RADIATION PROTECTOR CIRCUIT TEST
After service has been performed on the horizontal
deflection system, high voltage system, B+ system,
test the X-Radiation protection circuit to ascertain
proper operation as follows:
1. Apply 220V AC using a variac transformer for accurate
input voltage.
2. Allow for warm up and adjust all customer controls
for normal picture and sound.
3. Receive a good local channel.
4. Connect a digital voltmeter to TP653 and make sure
that the voltmeter reads 21.1
±
1.5 V.
5. Apply external 27.9V DC at TP653 by using an
external DC supply, TV must be shut off.
6. To reset the protector, unplug the AC cord and make
a short circuit between TP651 and TP652. Now make
sure that normal picture appears on the screen.
7. If the operation of the horizontal oscillator does not
stop in step 5, the circuit must be repaired before the
set is returned to the customer.
HIGH VOLTAGE CHECK
High voltage is not adjustable but must be checked
to verify that the receiver is operating within safe
and efficient design limitations as specified checks
should be as follows:
1. Connect an accurate high voltage meter between
ground and anode of picture tube.
2. Operate receiver for at least 15 minutes at 110~220V
AC line voltage, with a strong air signal or a properly
tuned in test signal.
3. Receive a good local channel.
4. The voltage should be approximately, 23.5kV (at
picture MAX, Bright center condition).
If a correct reading cannot be obtained, check circuitry
for malfunctioning components. After the voltage test,
make Y-mute off to the normal mode.
INSTALLATION AND SERVICE INSTRUCTIONS
Note:
(1) When performing any adjustments to resistor controls and transformers use non-metallic
screwdrivers or TV alignment tools.
(2) Before performing adjustments, the TV set must be on at least 15 minutes.
Summary of Contents for 14AR22
Page 14: ...13 14AR22 CHASSIS LAYOUT 6 5 4 3 2 1 A B C D E F G H ...
Page 15: ...14 14AR22 6 5 4 3 2 1 A B C D E F G H BLOCK DIAGRAM ...
Page 17: ...17 14AR22 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN UNIT ...
Page 18: ...17 14LK22 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN UNIT ...
Page 19: ...17 14LK22 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN UNIT ...
Page 20: ...18 14AR22 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CRT Units ...
Page 22: ...20 14AR22 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Wiring Side ...
Page 23: ...21 14AR22 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Chip Parts Side ...
Page 30: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...