12
14AR22
CRT CUT-OFF, BACKGROUND AND SUB-CONTRAST ADJUSTMENT
No. Adjusting point
Adjusting procedure/conditions
Waveform and others
CRT CUTOFF
ADJUSTMENT
(I
2
C BUS
CONTROL)
1. Switch TV to VIDEO mode,BLUE BACK OFF, with
NO VIDEO signal.
2. Press R/C to set Picture Normal condition.
3. Connect the oscilloscope to Red OUT from
IC801.(TP47R)
Range
: 1 V/Div (DC)
Sweep
: 5 msec/Div
4. Adjust SCREEN VR ,so that the tip of signal reach
3.0 Vdc + 0.1 Vdc.
1
1 V
3.0Vdc
0
Maximum
beam check
1. Receive the "Monoscope Pattern" signal.
2. Press R/C to set Picture NORMAL condition.
3. Connect the DC miliammeter between TP603 (+)
and TP602 (–).
(Full Scale: 3 mA Range)
4. Beam current must be within 720
±
50
µ
A.
4
SUB-BRIGHT-
NESS
ADJUSMENT
(I
2
C BUS
CONTROL)
1. Call " SUB-BRI" in service mode. (Receive Cross-
hatch pattern with 5 black level windows)
2. Adjust the " SUB BRIGHT " bus data in order that
the line 1, 2 and 3 have the same darkness
wherelse line 4 is slightly brighter than line 1, 2
and 3 and finally line 5 will be the brighter than
line 4.
2
1, 2, 3 are in same black level.
WHITE BAL-
ANCE SERV-
ICE MODE
ADJ. (I2C BUS
CONTROL)
3
# 11,600
°
K
X : 0.273
Y : 0.280
( MINOLTA COLOUR ANALYZER
CA-100)
*NOTE: Above DATA can be UP/
DOWN by volume key.
LOW
HIGH
14"
1.8cd/m
2
115cd/m
2
* 11,600
°
K
DRI-GW="DRI-GS"DATA-5
DRI-BW="DRI-BS" DATA-5
1. Receive the "Monoscope Pattern" signal.
2. Press R/C to set Picture NORMAL condition.
3. Connect the DC miliammeter between the TP 602
( - ) TP 603 ( + ).
4. Check Beam current should be around (720
µ
A)
5. Set it to service mode and adjust the DRI-G-MH,
& DRI-B-MH data to have a colour temperature
of 11,600
°
K ( white ).
6. Receive "WHITE" pattern, WITH BURST signal,
and set BRIGHTNESS Y by generator, to ** 10
cd/m2 (MINOLTA CA-100) by reducing LUMINATE
Y signal.
7. Adjust "CUT-R" & "CUT-G" to get 11,600
°
K. Then
go back NORMAL mode (HIGH BRIGHT**) to
check colour temperature. If out of range, back
to (1).
Note: This adjustment must be done after
warming up the unit for 30 minutes or
longer with a beam current over 500
µ
A.
DRI-R-MH=32
(FIXED)
DRI-G-MH=33
(FIXED)
DRI-B-MH=37
(FIXED)
DRI-R-MH=32
(FIXED)
1 2 3 4 5
Summary of Contents for 14AR22
Page 14: ...13 14AR22 CHASSIS LAYOUT 6 5 4 3 2 1 A B C D E F G H ...
Page 15: ...14 14AR22 6 5 4 3 2 1 A B C D E F G H BLOCK DIAGRAM ...
Page 17: ...17 14AR22 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN UNIT ...
Page 18: ...17 14LK22 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN UNIT ...
Page 19: ...17 14LK22 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN UNIT ...
Page 20: ...18 14AR22 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CRT Units ...
Page 22: ...20 14AR22 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Wiring Side ...
Page 23: ...21 14AR22 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Chip Parts Side ...
Page 30: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...