Electrical Connections 

WARNING 

 

The pump must be earthed. 

 

The pump must be connected to an external mains switch with a contact separation 
gap of at least 3mm in each pole. 

 

The pump must be connected to a 230V, 50Hz supply with a switched spur fused at 
5A (10A on model BP130D). 

 

Metal pipes must be earthed by the use of earthing clamps to BS 951 and 4mm 
earthing wire. Where the earth continuity has been broken by flexible pipes the pump 
discharge and suction pipe work should be connected with earthing clamps to BS 951 
and 4mm earthing wire. 

CAUTION 

 

Complete all pipework before making electrical connections. 

 

Do not allow any water to enter into the electric terminal box. 

If in doubt - consult a qualified electrician. 
Connect using the following colour code: 

 

BROWN to terminal L (Live). 

 

YELLOW/GREEN to terminal E (Earth). Ensure that the earth lead is at least as long 
as the other two leads. 

 

BLUE to terminal N (Neutral). 

Insert the lead fully into the terminal connector and tighten the screw firmly. Ensure that the 
connection is secure. Be sure to tighten the cable restraint. 
Ensure compliance with the IEE Wiring Regulations (BS 7671). 
In the interests of safety it is recommended that a residual current device (RCD) be 
installed in the supply circuit. 

WARNING

 

Do not operate pump without the terminal cover in place. 
The pump switch should be left on at all times for normal operation of the system. 

Summary of Contents for AP265

Page 1: ...et See figure 1 page 6 for installation diagram The pump cannot operate if the level of the water in the cold water storage tank is below the level of the pump Do not fit non return valves in the inle...

Page 2: ...flow switches on there must be a minimum height between the cold water storage tank and the highest point of the outlet pipework of approximately 250mm see Figure 1 page 6 The pump must be installed i...

Page 3: ...old water supply to the hot water cylinder to prevent the supply of hot water only It does not matter which end of the pump is connected to the cold water supply Ensure that the cold water supply is c...

Page 4: ...al connections Do not allow any water to enter into the electric terminal box If in doubt consult a qualified electrician Connect using the following colour code BROWN to terminal L Live YELLOW GREEN...

Page 5: ...e pump is not used for long periods 8 It is recommended that the pump is run for 5 minutes or more at least once every four weeks in order to prevent the pump seizing Servicing The flexible pump hoses...

Page 6: ...6 Figure 1 Recommended installation of positive head pumps...

Page 7: ...ossible to avoid trapped air Pipework from the pump to the shower valve should go up and over rather than under floor Avoid blanked off pipes dead legs which can trap air and cause problems Avoid kink...

Page 8: ...o hang into the shower tray or bath Operate maximum hot and cold flow for at least 2 minutes each Ensure there are no leaks in the system and that all taps and outlets are off Purge any air in the sys...