22
Deutsch
English
4.4 Charging operation with batteries connected in series
With serially connected batteries, each battery requires its own charger for charging.
4.5 Charging operation with larger battery banks
In this case, too, Torqeedo recommends use of one charger per battery. However, it is
possible to use one charger for a maximum of two batteries connected in parallel. Char-
ging time will be twice as long.
5. Installation
The charger is designed to be positioned as a free standing or wall mounting unit.
6. Errors and possible troubleshooting
Display/
Error LED flashing interval
Cause/
Error message
What should be done?
Green “Mains“ LED does not
flash with connected battery,
charging process is not
being started.
Please check whether the plug has properly been
plugged into the socket and whether the socket is
functional.
If the power supply and connection are not the
reason for the failure, please contact a Torqeedo
Service Center in your vicinity – contact data can be
found on the back of this manual.
Red „Error“ lamp displays
recurrent simple flashing
signal
Damaged or deeply
discharged battery
Contact a Torqeedo Service Center in your vicinity
– you‘ll find the corresponding contact data on the
back of this manual.
Red „Error“ lamp displays
recurrent double flashing
signal
Battery voltage too
high or incorrect
battery connected
Check whether the charger is connected to the cor-
rect battery. If this is the case and battery cannot be
charged, please contact a Torqeedo Service Center.
Red „Error“ lamp displays
recurrent quintuple flashing
signal
Device temperature
too high to start
charging process
Wait until the correct temperature will be reached
(refer to Technical data, page 18).