8-6
Z Master 7500-D Series Service Manual
March 2018 - Digital Edition
ELECTRICAL
Fuse Block and Fuses
The fuse block houses the fuses that protect the electrical system from electrical surges (Figure 3).
NOTE: Always use OEM fuses when replacing a damaged or blown fuse.
Testing
1. Visual Inspection
: The fuses used in this application may be visually inspected. A failed fuse can be identified
by a broken or melted element inside the fuse cover or a damaged spade (Figure 4).
2. Using a digital multi-meter set to the OHM or continuity setting, check the continuity between the fuse blades. If
the fuse is OPEN (no continuity), replace the fuse and test the circuit.
Figure 3
Figure 4
Bad
Good
Summary of Contents for Z Master 74060
Page 178: ...L C EP r o d u c t s...