background image

Introduction

The Toro Wireless RainSensor connects to your irrigation system controller/timer to
suspend automatic watering operation in the event of rain. Designed for ease of
installation, your sensor-controlled irrigation system will be up and running in minutes. 

Before attempting the installation, please read through these instructions in their
entirety, and refer the installation instructions for your irrigation system controller/timer
in regards to connecting a rain sensor or rain switch. The Wireless RainSensor is
designed to work with either Normally Open or Normally Closed sensor circuits.

Important:

Please note the following information regarding installation and use

of the Wireless RainSensor components:

• The RainSensor Receiver is designed to operate with 24 V ac power only.

Connecting the Receiver wiring to 120/240 V ac power may result in severe
equipment damage. 

• Installation methods must comply with all applicable national and local building

codes. If you are unsure about proper wiring practices, have a qualified contrac-
tor perform the installation for you. 

• The Receiver cover should always be used when the Receiver is installed out-

doors.

• The Sensor/Transmitter should never be submerged in water or installed inside a

rain gutter.

Contents

Page

Component Overview . . . . . . . . . . . . . . . .2
Quick Start Installation Instructions . . . . . .3
Detailed Installation Instructions  . . . . . . . .4

• Mounting the Receiver  . . . . . . . . . . . . .4
• Receiver Control Wire Connection . . .4-5
• Receiver Power Wire Connection  . . . . .6
• Initial Receiver Testing  . . . . . . . . . . . . .7
• Rainfall Adjustment  . . . . . . . . . . . . . . .7
• Sensor/Transmitter Installation   . . . . . .7
• Testing Signal Strength  . . . . . . . . . . . .7
• Testing Control System Operation  . . . .7
• Installing the Sensor/Transmitter  . . . . .8

Wireless RainSensor Operation  . . . . . . . .9

• Normal Operation . . . . . . . . . . . . . . . . .9
• Smart Bypass  . . . . . . . . . . . . . . . . . . .9
• Power Down  . . . . . . . . . . . . . . . . . . . .9
• Receiver Learn Mode . . . . . . . . . . . . . .9
• Attention Required  . . . . . . . . . . . . . . . .9

Battery Replacement  . . . . . . . . . . . . . . .10
Changing Sensor/Transmitter Code  . . . .10
Troubleshooting . . . . . . . . . . . . . . . . .10-11
Electromagnetic Compatibility  . . . . . . . . .11
Specifications . . . . . . . . . . . . . . . . . . . . .12
Warranty  . . . . . . . . . . . . . . . . . . . . . . . .12

Receiver 

Sensor/Transmitter

Wireless RainSensor

Model 53770

User’s Guide

Summary of Contents for Wireless RainSensor 53770

Page 1: ...ion methods must comply with all applicable national and local building codes If you are unsure about proper wiring practices have a qualified contrac tor perform the installation for you The Receiver...

Page 2: ...tion will reset automatically To man ually exit the bypass mode press button again 6 Power Indicator Steady light 24 V ac power is connected Blinking light Sensor Transmitter battery power low or othe...

Page 3: ...e controller s 24 V ac power source terminals 5 Straighten the Receiver antenna wire upward and the Sensor Transmitter antenna wire downward 6 While holding the Sensor Transmitter at close range to th...

Page 4: ...he common wire of the valves or they can be connected directly to the sensor input terminals of the controller if provided 1 Disconnect power to the controller 2 Follow applicable wiring procedure A o...

Page 5: ...to include the common wire from the pump start relay or master valve in this connection Attach the Brown wire to the valve common terminal Note The yellow wire is not used in this application 5 COM PU...

Page 6: ...and 24 and Hot Post and 24 Verify correct volt age then simply attach the two Red power wires to these terminals leaving existing connections in place On controllers with no 24 V ac terminals connect...

Page 7: ...ct with spray from the sprinklers or runoff from the roof Testing Signal Strength at the Installation Site Before installing the Sensor Transmitter test the signal strength again from the select ed in...

Page 8: ...nd tighten to secure do not over tighten See Figure 7 The Sensor Transmitter can also be mounted on any suitable solid structure such as the side of the roof a shed or fence using the two supplied sta...

Page 9: ...ld the Smart Bypass button until the Sensor Status Indicator begins blinking rapidly 5 7 seconds Release the Smart Bypass button and confirm the Power Indicator goes out and flashes periodically Simpl...

Page 10: ...s small black wire and white wire loops and cut one or both loops using end cutting pliers 3 Reassemble the Sensor Transmitter and follow the procedures provided in Receiver Learn Mode on page 9 Troub...

Page 11: ...other words passing diagonally through a wall increases its effective thickness Because every installation is differ ent the ONLY guaranteed method to verify an installation is to physically TRY IT E...

Page 12: ...ucts During such warranty period we will repair or replace at our option any part found to be defective Return the defective part to the place of purchase Our liability is limited solely to the replac...