![Toro TBC WP User'S Manual And Installation Instructions Download Page 6](http://html1.mh-extra.com/html/toro/tbc-wp/tbc-wp_users-manual-and-installation-instructions_1131319006.webp)
6
Connecting the Rain Sensor
The TBC
TM
WP sensor is designed for a normally closed sensor.
The following example will illustrate how to connect a wired Toro RainSensor
TM
to the
controller. Other normally closed sensors can be installed to the controller as well, such as
moisture, rain, etc.
Step 1 –
Route wires from the rain sensor to
the TBC
TM
WP controller.
Step 2 –
Cut the wire loop (yellow) from
TBC
TM
WP controller’s Sensor A and B.
Strip approximately 1/2" (1.25 cm)
of insulation from the wires and
connect them to the rain sensor wires.
Wire polarity is not observed in this
application.
NOTE:
Use water sealed/proof
wire connectors (not supplied) for this
application.
IMPORTANT:
If a rain sensor is not
installed, the TBC
TM
WP controller’s
Sensor A and B wires must be
connected together. Otherwise, the
controller will assume that rain is
being detected and it will prevent
programs from activating.