6

Connecting the Rain Sensor

The TBC

TM

WP sensor is designed for a normally closed sensor.

The following example will illustrate how to connect a wired Toro RainSensor

TM

 to the 

controller. Other normally closed sensors can be installed to the controller as well, such as 
moisture, rain, etc.

Step 1 – 

Route wires from the rain sensor to 
the TBC

TM

WP controller.

Step 2 – 

Cut the wire loop (yellow) from 
TBC

TM

WP controller’s Sensor A and B. 

Strip approximately 1/2" (1.25 cm) 
of insulation from the wires and 
connect them to the rain sensor wires. 
Wire polarity is not observed in this 
application.

 

NOTE:

 

Use water sealed/proof 

wire connectors (not supplied) for this 
application.

 

IMPORTANT:

 If a rain sensor is not 

installed, the TBC

TM

WP controller’s 

Sensor A and B wires must be 
connected together. Otherwise, the 
controller will assume that rain is 
being detected and it will prevent 
programs from activating.

Summary of Contents for TBC WP

Page 1: ...s Two 9 Volt Batteries Not Included Operates DC Latching Solenoids Sensor Compatible Non Volatile Memory Operate Valves Up to 200ft 61m When Using 18 AWG Integrated Infrared Interface With Optional In...

Page 2: ...t AWG 18 1 0mm2 Multi Strand Wire 200ft 61m AWG 16 1 5mm2 Multi Strand Wire 305ft 100m AWG 14 2 5mm2 Multi Strand Wire 500ft 150m AWG 12 4 0mm2 Multi Strand Wire 820ft 250m TBCTM WP Station Output Pow...

Page 3: ...s of irrigation run time per station Day of the week 31 day interval Odd and Even watering schedules with day exclusions 0 300 monthly water budgeting in 10 increments Manual semi auto or auto activat...

Page 4: ...solenoid and unscrew it from the valve Step 3 Install the DC Latching solenoid onto the valve Step 4 Strip approximately 1 2 1 25 cm of the insulation from the DC Latching solenoid s wires Step 5 Ref...

Page 5: ...tep 2 Connect the TBCTM WP controller s station 1 wire to the positive red wire lead from Station 1 solenoid Connect the TBCTM WP controller s C common wire black to the negative black solenoid wire C...

Page 6: ...ontroller Step 2 Cut the wire loop yellow from TBCTM WP controller s Sensor A and B Strip approximately 1 2 1 25 cm of insulation from the wires and connect them to the rain sensor wires Wire polarity...

Page 7: ...nscrew the battery cap to access the battery compartment Step 2 Install two 9 VDC alkaline batteries onto the two battery connectors located inside the compartment IMPORTANT Make sure no water is pres...

Page 8: ...box Step 2 Secure the two mounting screws on the marked location Leave approximately 1 4 6mm of the exposed screw Step 3 Hang the controller onto the screws Verify that the screws are seated properly...

Page 9: ...the batteries are connected properly Possible Cause The TBCTM WP controller IR port is dirty Solution Clean the TBCTM WP IR port Possible Cause Improper connection between hand held and controller So...

Page 10: ...y proper operation of that sensor Possible Cause Short circuit in the solenoid or the wiring to the solenoid Solution Verify with TBCTM WP Programmer that a short was detected on the station If a shor...

Page 11: ...ed in any manner contrary to Toro s specifications and instructions nor where equipment is altered or modified Neither The Toro Company nor Toro Warranty Company is liable for indirect incidental or c...

Page 12: ...be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the irrigat...