DIAGNOSTICS

Built-in Diagnostics

If the user selects DIAGNOSTICS MODE from the Configuration Menu, the OSMAC Base Station goes into a diagnos-
tics mode. This mode allows the operator to exercise many of the Base Station’s hardware functions and help trou-
bleshoot any problems with connections to the unit. Connections to the phone line, radio, speaker and microphone may
be independently toggled for testing.

The Functions that are available are:

F1 - Toggle the connection of the phone line between On and Off
F2 - Toggle the Base Station radio connection between Off, Receive and Transmit modes
F3 - Toggle the unit microphone connection between On and Off
F4 - Toggle the unit speaker between On and Off

1 – Satellite Bit Test (sends alternating 1010 pattern at a specific baud rate)

1 – 512 baud
2 – 1200 baud
3 – 2400 baud

2 – Sound Tests

– Press any of the number keys to play one of the first 10 sounds
– Press the up arrow key to select additional sounds

3 – DTMF tests

– Press one of the 16 lower buttons to generate DTMF tones in “encode” modes
– Press the down arrow key to exit the DTMF test mode
– Press the up arrow key to toggle between the following test modes:

- Encode DTMF continuously
- Decode DTMF from the radio or phone line, depending on which was enabled last
- Encode DTMF in 50 mS beeps
- Encode only the low tone continuously
- Encode only the high tone continuously

4 – DAC ramp test (exercises the sound DAC) 

– Press the number keys to change the ramp frequency

5 – LCD display tests

– Press the “” key to sequence between the tests

6 – Keypad and keyboard test

– Keypad codes and external keyboard scan codes are displayed when keys are pressed
– Press the “” key on the keypad twice to exit this test mode

7 – Alarm inputs (displays the status of the alarm inputs)

Remote Diagnostics

Test functions may also be initiated remotely via a two-way radio which is equipped with a 16 tone DTMF keyboard.

Key Sequence

Function 

* A

Send an “A” DTMF tone to the radio and the phone line continuously for a period of time.

* B

Send all 16 DTMF tones plus all 8 single tones to the radio and the phone line.

* D

Transmit the CW Identification Call Sign in Morse Code. CTCSS is turned on.

7

 

RELEASED Version  ©Toro 2006-2006

Summary of Contents for OSMAC

Page 1: ...OSMAC Base Station Digital Wireless Paging System Field Service Guide RELEASED Version Toro 2006 2006 ...

Page 2: ...2 RELEASED Version Toro 2006 2006 ...

Page 3: ...a Command 9 Manual Entry of a Command 9 TAP Protocol Timing Issues 9 TAP Protocol Line Feed Issues 9 XOFF 9 EOT 9 Sending Multiple Line Commands 9 Computing the Checksum 10 COMP1 10 COMP2 10 ASCII Control Character Table 10 DATABASE TRANSFER 11 Database Format 11 Retrieving the Database 12 Restoring Uploading the Database 13 Erasing Satellite or Groups from the Database 13 Programming Two Tone Sat...

Page 4: ...E 7 WARMUP SIGNAL ENABLE DISABLE 4 TRANSCEIVER 1 TX SETUP 1 TX FREQUENCY 464 5 MHZ 2 TX SIGNALING 1 CARRIER ONLY 2 CTCSS 3 TX BANDWIDTH NARROW BAND WIDE BAND 2 RX SETUP 1 RX FREQUENCY 464 5 MHZ 2 RX SIGNALING 1 CARRIER ONLY 2 CTCSS 3 INVERT CARRIER DETECT YES NO 4 INVERT TRANSMIT DATA YES NO 5 TX TYPE NO TYPE SELECTED VHF UHF 260 MHZ 5 CW CALL SIGN DEFAULT NONE 6 DIAGNOSTIC MODE See Diagnostic Mod...

Page 5: ...Configuration menu enter 3 for Mode Selection then enter 1 for the Speaker Enable selection Busy Channel Lockout If this mode is enabled the OSMAC Base Station will not transmit while the channel is busy This may be desirable to avoid interfering with other users on the same channel This mode can be disabled when other activities on the channel prohibits base station transmission in a timely manne...

Page 6: ...s mode press 1 to select CARRIER ONLY Press the F1 key to save configuration and to exit the menu To access Transmit Signaling from the Transceiver Setup menu enter 1 for Transmit Setup then enter 2 for Transmit Signaling To access Receive Signaling from the Transceiver Setup menu enter 2 for Receive Setup then enter 2 for Receive Signaling CTCSS operation should be used when other users are shari...

Page 7: ...tons to generate DTMF tones in encode modes Press the down arrow key to exit the DTMF test mode Press the up arrow key to toggle between the following test modes Encode DTMF continuously Decode DTMF from the radio or phone line depending on which was enabled last Encode DTMF in 50 mS beeps Encode only the low tone continuously Encode only the high tone continuously 4 DAC ramp test exercises the so...

Page 8: ...order and sequence of characters sent over the serial interface to the transmitter The transmitter must parse the commands and take the appropriate actions The following sections describe how the TAP protocol works It assumes that the device communicating with the OSMAC Base Station is directly connected via a serial cable If other means are used i e modem then the modem connection must first be e...

Page 9: ...ice to disconnect This go ahead sequence tells the entry device that it is OK to go ahead and send over the information for the first com mand s The p is always the lower case p This Satellite Command Sequence Block tells the base sta tion the ID the satellite ID Code in the satellite database of the satellite the command is to be sent to The checksum is computed as shown in this document The tota...

Page 10: ... line satellite The OSMAC Base Station will translate the TAB char acter to a CR when it transmits the command to the satellite Entry Device M CR Satellite ID CR Command CR OSMAC Base Station Action ENTER PAGER NUMBER Enter Alpha Message or Enter Numeric Message Sending Message CR Message Sent CR or Can t Deliver to XXXXXXX CR or Too Slow Goodbye CR or Too many errors Goodbye CR Comment The entry ...

Page 11: ...is transaction and begin waiting for a new Satellite entry Manual Entry of a Command ASCII control characters For your reference here is a table of the commonly used ASCII control characters Decimal Hex Code Decimal Hex Code 00 00 NUL 16 10 DLE 01 01 SOH 17 11 XON 02 02 STX 18 12 DC2 03 03 ETX 19 13 XOFF 04 04 EOT 20 14 DC4 05 05 ENQ 21 15 NAK 06 06 ACK 22 16 SYN 07 07 BEL 23 17 ETB 08 08 BS 24 18...

Page 12: ...N Firmware version string OPTIONS Firmware options SERIAL Signifies that this line is data for a serial port PORT Port number for this line s data BITS Number of data bits 0 7 bits 1 8 bits STOP Number of stop bits 0 1 bit 1 2 bits PARITY Parity 0 No Parity 1 Odd 2 Even FLOW Flow control 0 None 1 Xon Xoff 2 RTS CTS BAUD Baud rate 0 300 1 600 2 1200 3 2400 4 4800 5 9600 6 19200 TAP TO Timeout for T...

Page 13: ...ollow this one and are separated by commas MEMBER N This is the satellite number for the final member of the satellite group DONE This entry signifies the end of the database Retrieving the Database The OSMAC Base Station will send the contents of its database out the serial port when it is given the command ESC SDB CR The database is transmitted out at the currently configured baud rate in an ASC...

Page 14: ...t must be configured for TAP protocol The Base Station will answer every line that is sent with an OK if the line is acceptable or ER if there is an error If any error s occur during uploading a message will be displayed at the end of the upload sequence and the information received will not be saved If this occurs reduce the data rate transfer of the communication port in use or enable the hardwa...

Page 15: ...word required to access the Configuration Mode from the OSMAC Base Station s front panel FIRMWARE UPDATE The OSMAC Base Station firmware can be loaded with firmware updates via the serial port number 1 Note The user might need to reset the Flash memory and reload the database of satellites after you load the new firmware into the unit Before updating the firmware it is recommended for the user to ...

Page 16: ... 2000 The Toro Company Irrigation Division Form Number 373 0133 Rev A RELEASED Version Toro 2006 2006 ...

Reviews: