Introduction

The OSMAC Satellite is designed for installation on a substantial concrete foundation with embedded conduit of various 

diameters to enable power, field and earth ground wiring to be routed into the cabinet. A mounting bolt positioner and 

basic mounting hardware components are included with each satellite. Additional materials required to complete the 

installation must be obtained separately. A material list can be compiled by reading through the instructions completely 

prior to starting the installation.

CAUTION: For your protection and the safety of the product user, comply with all Caution and Warning Statements 

within this document. All installation practices must comply with all applicable national and/or local electrical and 

construction codes. 

Foundation Construction

1.  Prepare a hole for the foundation       

Figure 1

Wood Form

See *Note

Concrete

Mounting Bolt w/ Hex Nuts

(Typical 4 Places)

2" (51mm) Max

6" (15.2cm)

Mounting Bolt 

Positioner

30"

(76cm)

30"

(76cm)

2"

(51mm)

Taper

Plastic Cabinet Base Area

Metal Cabinet Base Area

Mounting Bolt Positioner

3" (76mm) Conduit - Field

(32 Stations Each)

3/4" (19mm) Conduit

Earth Ground

3/4" (19mm) Conduit

AC Power

 

and wiring conduit using the 

minimum recommended dimensions 

shown in Figure 1.

 

*Note: Refer to local electrical 

codes for required depth of buried 

wiring.

2.  Trench to the foundation site as 

required for each wiring run.

3.  Position the straight and sweep 

elbow conduit sections in the 

foundation hole as shown. Tape 

the conduit ends to seal out dirt. 

Backfill soil to form a 6" (15.2cm) 

foundation depth. Conduit should 

not extend more than 2" (51mm) 

above the finished top surface of the 

foundation.

4.  Prepare the sides of the foundation 

hole with wood forms.

5.  Prepare the mounting bolt positioner 

with the 5/16" x 4-1/2" bolts and 

nuts (provided) as shown in Figure 1.  

The threads should extend 2" 

(51mm) from the top surface of the 

bolt positioner.

6.  Pour concrete into the formed 

foundation hole. Press the mounting 

bolt positioner into the concrete 

until it is flush and level with the 

foundation surface and aligned with 

the conduit.

7.  Finish the concrete with a level flat 

area (16" x 16" [41cm x 41cm]). To 

prevent pooling at the base of the 

pedestal, add a slight taper away 

from the cabinet base contact area. 

Allow the concrete to sufficiently 

harden before continuing.

8.  Remove the hex nuts from the 

mounting bolts. Place the pedestal 

on the pad ensuring all bolts pass 

though the holes provided. Install a 

flat washer and a hex nut on each 

bolt and tighten securely. 

Summary of Contents for OSMAC Satellite

Page 1: ... 3 4 19mm Conduit AC Power and wiring conduit using the minimum recommended dimensions shown in Figure 1 Note Refer to local electrical codes for required depth of buried wiring 2 Trench to the foundation site as required for each wiring run 3 Position the straight and sweep elbow conduit sections in the foundation hole as shown Tape the conduit ends to seal out dirt Backfill soil to form a 6 15 2...

Page 2: ...und Rod 6 AWG 10mm2 Solid Copper Ground Wire 8 12 2 4m 3 7m 1 Drive a 5 8 16mm by 8 2 5m copper clad steel rod into well moistened soil not more than 12 3 7m from the satellite The top of the ground rod should be slightly below grade level 2 Using a 5 8 16mm clamp or Cad weld fastener attach a length of 6 6mm2 solid copper wire near the top of the ground rod Avoiding sharp bends route the wire thr...

Page 3: ... wiring access cover located on the back of the power supply assembly See Figure 4 Note The power and equipment ground wires are connected to a terminal block located on the back of the power supply assembly The power wire access hole provided will accommodate a 3 4 19mm conduit fitting If conduit is required by code install a section of flexible 3 4 19mm electrical conduit from the foundation con...

Page 4: ...lite through the 3 76mm conduit 2 If an automatic pump start is required refer to the applicable wiring diagram in Figure 5 and install accordingly CAUTION Do not connect the pump starter directly to the satellite s pump start circuit damage to the satellite will result Note The pump circuit can also be utilized to control a master valve if required 3 Secure the field common wire s and pump start ...

Page 5: ...and press SELECT SELECT to access 4 Use the or arrows to select Radio Frequency and press SELECT SELECT to access 5 While the cursor selection is on Channel 1 press SELECT SELECT to select Use the or arrows to scroll through the six pre programmed frequency channels Once the correct frequency is selected press SELECT SELECT to activate 6 If the desired frequency does not match any of the pre progr...

Page 6: ...s for a predetermined number of 30 second intervals already defined in the satellite e g 7512 01 02 turns on stations 1 and 2 for 30 second intervals 7513 Disables individual stations e g 7513 01 03 disables stations 1 and 3 After this command on and off commands will be ignored for stations 1 and 3 until the stations are re enabled See 7514 7514 Enables individual stations e g 7514 01 03 enable s...

Page 7: ...531 6108 will change the factory default password 7531 to 6108 8006 01 Sets the syringe time in 30 second intervals e g 8006 01 0100 without a password or 8006 pppp 01 0100 with a password sets the syringe time to 100 intervals 50 minutes The number of intervals must be given as four digits with leading zeros but can be no greater than 0255 8006 03 Enables disables the password Use 8007 03 01 to e...

Page 8: ...nt generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a FCC Class B computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules which are designed to p...