26
Checking and Clearing Alarms
Press the down arrow key
to advance the cursor to the
S001:
field. Use the input dial
to scroll through all
the stations with alarms. To clear the alarm, press the right arrow key
to the Alarm: field, use the Input Dial
to display Clear Alarm. Press the down arrow key
to execute.
Menu: Revision
Revision: 02.08
Rev. Date 01/04/11
Menu: RunDiagnostics
Perform: Comm Check
Press START to start
Use this menu to
verify firmware
version.
Use this menu perform a
Comm (Communication)
Check or a Solenoid Chk
(check).
Menu: PowerUp Detect
Capacity: 200 sta s
PD 06/28/11 13:53:51
PU 06/29/11 11:15:32
Menu: VA Monitor
Battery Volt: 3.3
LCD Voltage: 2.7
Board temp: 28c
Use this menu to monitor the
system’s voltages.
This menu will display
the detected station
capacity from the last
Power Down (PD).
PU will display the date
and time of the last
Power Up.
,
Total Timeouts: 001
Total Failed: 002
Clear Total: No
Menu: Link Monitor
Sent: GetPumpPress
Resp: 2nd
Total Bad Resp: 001
Menu: Event Codes
Clear log: No
Last code: 93
06/30/11 10:21:46
This menu will display the last
logged event that may help
diagnose problems. The event
code, date and time the event
occurred will be displayed. Clear
the log by navigating to “Clear
log: No” using the Right or Left
arrows
.
Use the input dial to toggle No
to Yes. Press the Up or Down
arrow to accept.
Use this menu to display
when and what messages
are sent.
1st Line: Name of the sent message
2nd Line: Response status
3rd Line: Number of messages that were sent out with bad responses
4th Line: Number of messages that did not get a response
5th Line: Number of messages that failed to communicate after
Use the arrow keys to navigate to Clear Total and toggle
No to Yes to clear all Link Monitor’s values.