Sensor Connection and Operation:

The DDCWP will respond to a Toro, TRS wired RainSensor

.  Cut the 

yellow looped wire from the controller, and using waterproof connectors,

connect the two wires from the rain sensor to either ends of the yellow

controller wires. 
The controller will respond to any normally closed (N.C.) wired RainSensor

.

Follow the manufacturers installation instructions.
Activation of the RainSensor

 cancels irrigation programs until the

RainSensor

™ 

returns to a closed status. 

NOTE: When irrigation is suspended due to the RainSensor

the display shows:

and the rain icon 

is displayed.

scaling from 0% to 200% in 10% increments.  

Season Adjust is set by month with the default setting 

being 100% of set runtimes. This water management feature allows you 

to stop irrigation for the months not requiring irrigation and ramp up the 

irrigation times as the irrigation season advances.

Dial position: SEASON ADJUST

In this dial position you can increase or decrease the 

RUN TIME of all stations in that program by percentage 

Press PROG to select the program you wish to percentage adjust.  The 

display will show 1:10%. This is January, month one, and it is set at 100%. 
Press "+/on" to increase watering percentage or "-/off" to decrease 

watering percentage.
Press NEXT to advance to the next month. Repeat steps above to increase 

or decrease watering percentage for the month displayed.

To set a program to "OFF"

If you wish to stop irrigation of a program, set percentage adjustment to 0%.
The display will show that program is OFF.
To resume normal operation of that program, set dial to "SEASON ADJUST"

and increase the percentage to your desired value. Increasing to 100% 

will set RUN TIME to its original value.
Press PROG to select the program.
Press DIAL to advance to MANUAL.

Dial position: MANUAL

The MANUAL mode allows immediate customized 

irrigation on one or more zones. You can set an 

individual RUN TIME for each of the stations you wish

to start manually. The controller has a "programmable manual" function, so

if you manually program more than one station, they will open in sequence.
Press +/ON or -/OFF to set the station RUN TIME.
Press NEXT to advance to next station.
To turn ON the 1st station in the sequence:
Press DIAL to AUTO-RUN position.
Press -/OFF (in AUTO-RUN position) to turn OFF the sequence.
All stations with a manually programmed RUN TIME will be displayed.

Operating stations will flash and the display will show the remaining RUN

TIME of the station (count down).
Press DIAL to advance to MANUAL PROGRAMS.

- 8 -

- 5 -

ddcwp_manual_gb_revised.ai  10/23/06  Page 5

Yellow RainSensor

™ 

wires