background image

Introduction

The  690  Series  Rotary  Sprinkler  is  designed  for  irrigation  of  large  turf  areas  such  as  golf  courses,  parks,
recreational fields and school grounds.

Manufactured from durable, high strength engineering plastic and stainless steel components, the 690 sprinkler
incorporates  many  innovative  and  time  proven  features  for  lasting,  maintenance-free  operation.  Some  of  these
features are listed below.

INSTALLATION & SERVICE INSTRUCTIONS
690 Series Rotary Sprinkler

Features

• Positive Spring Retraction -  Pulls  nozzle  and  cap  down  out  of  the
way of people and turf maintenance equipment.

• Three Nozzle Sizes - Multiple nozzle sizes provide 45.1 to 82.2 GPM
flow and produce watering radii from 78 to 108 feet.

• Long Life Gear Drive - Gear drive mechanism is vacuum-packed with
lubricant and isolated from water stream for long, trouble-free life.

• Valve-In-Head Models -  Permits  head-by-head  control  to  customize
turf  watering  for  various  topography  and  soil  conditions.  Multi-cycle  for
wind or runoff problems, frost control and dew removal without low-head
drainage.  Available  for  hydraulic  normally  open  or  24  Volt  electric
systems.

• Sprinkler Operating Mode - Electric valve-in-head models have three
modes  of  operation;  AUTO,  ON  and  OFF.  Mode  is  set  using  a  selector
tool inserted through the sprinkler body flange.

• Built-in Check Valve - Check-o-matic sprinklers utilize a check valve in
the  sprinkler  base  to  prevent  seepage  from  low  area  heads  after  valve
closure. Check valve will hold up to 35 feet of elevation differential.

• Two-Speed / 60°-120° Models -Provides for more even precipitation.
Runs at half speed in non-overlapping areas.

• Two-Speed / 180° Models  -Provides  for  more  even  precipitation
where only a selected area is covered by an overlap, such as is found on
greens. Runs at half speed in non-overlapping areas.

• Serviceability -All internal parts of the sprinkler are accessible through
the top of the sprinkler body.

Model 69X-06-XX

Model 69X-02-XX

Model 69X-01-XX

Specifications

• 78 ft. – 108 ft. Radius
• Pop-Up Nozzle and Cap - 

7

8

in.

• 1

1

2

in. NPT Female Thread Inlet

• Recommended Operating

Pressure: 60 – 100 PSI

• Maximum Pressure: 150 PSI
• Electric Models:

– Solenoid - 24 VAC 
– Inrush Current - .40 Amps
– Holding Current - .235 Amps

• Dimensions:

– Cap Diameter - 7

1

2

in.

– Flange Diameter - 10 in.
– Height - 16 in.

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for 69-01

Page 1: ...hydraulic normally open or 24 Volt electric systems Sprinkler Operating Mode Electric valve in head models have three modes of operation AUTO ON and OFF Mode is set using a selector tool inserted thr...

Page 2: ...e 1 Triple Swing Joints Base Nozzle Set Nozzle Set Nozzle Set Pressure 90 91 92 Size 3 8 in Size 7 16 in Size 1 2 in PSI Rad GPM Rad GPM Rad GPM 40 50 60 78 ft 45 1 87 ft 53 7 70 82 ft 48 6 91 ft 57 2...

Page 3: ...than 2 feet per second See Table 2 below 1 Use jockey pump only to fill system at velocity fill rate of less than 2 feet per second 2 Use quick coupler keys at all tees and greens with quick coupler v...

Page 4: ...thin the system and maintains a constant pressure for optimum sprinkler operation The 690 series pilot valve is factory set to regulate at 80 or 100 PSI depending on sprinkler model Sprinkler operatio...

Page 5: ...ine if closure is shut off valve or blockage and correct 6 Valve won t close a Leak in pilot valve assembly Replace pilot valve assembly Electric 69X 06 XX b Plugged supply screen on piston Clean or r...

Page 6: ...provided on edge of stator 10 Thoroughly clean and inspect all parts Replace parts as required Note If changing nozzle to a different size appropriate stator must also be installed to ensure proper r...

Page 7: ...tube and correctly seat the snap ring See Figure 6 NOTE It is possible to install the snap ring backwards upside down See inset in Figure 6 to insure that snap ring is installed in the correct manner...

Page 8: ...om sprinkler body and cut control tubing just below tube retainer Unless pilot valve has been previously removed control tubing length will be sufficient for re connection 4 Remove tube retainer and r...

Page 9: ...9973 Spring 100 lbs Blue 1 11 89 0029 Piston 1 12 89 0005 Diaphragm Assembly 1 SERVICE PARTS AND ASSEMBLIES 89 0009 Pilot Valve Assy 50 lbs Elec 89 0010 Pilot Valve Assy 65 lbs Elec 89 0011 Pilot Valv...

Page 10: ...100 PSI 4 Full Circle 06 NPT Electric Valve In Head 92 6 Full Circle 2 Speed 08 NPT NC Valve In Head 60 120 8 Full Circle 2 Speed Pressure Regulation available on 180 180 Electric NC VIH models only A...

Page 11: ...1 19 3 3355 Piston Assy Valve Drain 1 19 89 0937 Piston Assy Valve El Hyd NC 1 20 Body 690 See Service Items 1 21 9 6002 Adapter Tubing Threaded 1 4 1 22 89 8157 Cap Poly 1 4 1 23 900 40 Retainer Tube...

Page 12: ...2001 The Toro Company Irrigation Division An ISO 9001 Certified Facility Form No 366 0041 Rev B All manuals and user guides at all guides com...

Reviews: