g191300
Figure 107
1.
Flange (coupling adapter)
3.
Section-manifold valve
2.
Flange (section-manifold
valve)
4.
Flange clamps
4.
For left or right section-valve manifolds, remove
the 2 flange-head bolts (1/4 x 3/4 inch) and
2 flange locknuts (1/4 inch) that secure the
section-valve manifold to the valve support
(
).
g191304
Figure 108
1.
Flange locknut (1/4
inch—left and right
section-valve manifold
positions)
4.
Flange (coupling adapter)
2.
Section-bypass valve
5.
Gasket
3.
Quick-connect fitting
(section-valve manifold)
6.
Flange-head bolt (1/4 x
3/4 inch—left and right
section-valve manifold
positions)
5.
Move the section-valve manifold and gaskets
down to clear the section-bypass valve and then
away from the machine (
).
Note:
If needed, loosen the mounting hardware
for the left or right section-valve manifolds as
needed to provide clearance.
Note:
Retain the flange clamps, gaskets and
quick-connect pins for installation in
the Section-Manifold Valve (page 80)
.
Cleaning the Manifold Valve
1.
Position the valve stem so that it is in the closed
position (
g027562
Figure 109
1.
Valve open
2.
Valve closed
2.
Remove the 2 end-cap-fitting assemblies from
each end of the manifold body (
and
).
78