maintenance reminder by pressing down on the
multi-function switch.
You can exit the
Service Engine
screen at any
time by turning the key to either the O
FF
or the
S
TART
position.
Alerts and Error Messages
The system is capable of displaying the following
errors:
•
Voltage Error
This occurs when the Key-Run voltage is less than
12.3 or greater than 16, a voltage error flashes.
The LED flashes a red light.
g030966
Figure 19
•
Valve Solenoid Open Error
If either 1 of the 2 valve solenoids disconnect, the
number
6
displays in the lower left corner of the
screen. The LED flashes a red light.
g030971
Figure 20
1.
Number 6 displays
•
Valve Solenoid Overcurrent Error
If an overcurrent event occurs, the number
2
displays in the lower left corner of the screen.
Check the valve solenoid and inspect it for damage
and wear. The LED flashes a red light.
g030972
Figure 21
1.
Number 2 displays
•
Valve Solenoid Connection Error
The system displays the
Valve Solenoid
Connection Error
alert and the LED flashes red
when the system detects an error. If the valve
solenoids are connected incorrectly (i.e. the
connector for the relief valve is connected to the
other valve solenoid) the tines do not operate until
the fault is corrected.
g030977
Figure 22
20