Checking and Adjusting the
Auger/Impeller Cable
Service Interval:
After the first 2 hours—Inspect the
auger/impeller cable and adjust it if
necessary.
Yearly—Inspect the auger/impeller cable and
adjust or replace it if necessary.
1.
Remove the 2 screws that are holding the belt
cover in place (
).
2.
Remove the belt cover (
g323250
Figure 30
3.
With the auger/impeller lever disengaged,
ensure that the gap between the auger clutch
arm and the frame of the machine is 1.5 mm
(1/16 inch) as shown in
.
g260108
Figure 31
1.
1.5 mm (1/16 inch)
3.
Auger clutch arm
2.
Frame
4.
If the auger/impeller cable is not properly
adjusted, do the following steps:
5.
Loosen the jam nut (
g322960
Figure 32
1.
Jam nut
2.
Turnbuckle
6.
Loosen or tighten the turnbuckle that adjusts the
tension on the cable (
7.
Adjust the turnbuckle until you obtain the proper
gap.
8.
Tighten the jam nut.
9.
Insert the 2 screws that you previously removed
on the belt cover.
10.
If the auger/impeller cable is properly adjusted
but a problem remains, contact an Authorized
Service Dealer.
Checking the
Auger-Gearbox-Oil Level
Service Interval:
Yearly—Check the auger-gearbox
oil and add oil if necessary.
1.
Move the machine to a level surface.
2.
Clean the area around the pipe plug and remove
the pipe plug from the gearbox (
Note:
If needed, use pliers to assist in removing
the pipe plug.
19
Summary of Contents for 38870
Page 2: ......
Page 12: ...g326777 Figure 11 Using Recoil Start g260415 Figure 12 10 ...
Page 29: ......
Page 67: ...g326777 Figure 11 Utilisation du lanceur g260415 Figure 12 10 ...
Page 86: ...Remarques ...
Page 87: ...Remarques ...
Page 89: ......
Page 99: ...g326777 Figuur 11 Handstart gebruiken g260415 Figuur 12 10 ...
Page 118: ...Opmerkingen ...
Page 120: ......