Checking and Adjusting the
Auger/Impeller Cable
Service Interval:
After the first 2 hours—Inspect the
auger/impeller cable and adjust it if
necessary.
Yearly—Inspect the auger/impeller cable and
adjust or replace it if necessary.
1.
Remove the 2 screws that are holding the belt
cover in place (
).
2.
Remove the belt cover (
g260066
Figure 34
3.
With the auger/impeller lever disengaged,
ensure that the gap between the auger clutch
arm and the frame of the machine is 1.5 mm
(1/16 inch) as shown in
.
g260108
Figure 35
1.
1.5 mm (1/16 inch)
3.
Auger clutch arm
2.
Frame
4.
If the auger/impeller cable is not properly
adjusted, do the following steps:
5.
Loosen the jam nut (
g322960
Figure 36
1.
Jam nut
2.
Turnbuckle
6.
Loosen or tighten the turnbuckle that adjusts the
tension on the cable (
7.
Adjust the turnbuckle until you obtain the proper
gap.
8.
Tighten the jam nut.
9.
Insert the 2 screws that you previously removed
on the belt cover.
10.
If the auger/impeller cable is properly adjusted
but a problem remains, contact an Authorized
Service Dealer.