Checking and Adjusting the
Traction Cable
Service Interval:
After the first 2 hours—Inspect
the traction cable and adjust it if
necessary.
Yearly—Inspect the traction cable and adjust or
replace it if necessary.
If the machine does not drive in the forward or reverse
speeds or it drives when you release the traction lever,
adjust the traction cable.
If the left (traction) cable is not properly adjusted, do
the following steps:
1.
Loosen the jam nut.
2.
Engage the traction lever and hold it in place
(
).
g001011
Figure 32
3.
Loosen or tighten the turnbuckle to adjust the
spring length to 5.5 cm (2.18 inches) as shown
in
g030998
Figure 33
1.
Jam nut
3.
Spring
2.
Turnbuckle
4.
5.5 cm (2.18 inches)
4.
Tighten the jam nut (
), ensuring there
is slight tension on the cable.
5.
If the traction cable is properly adjusted but a
problem remains, contact an Authorized Service
Dealer.
Checking and Adjusting the
Auger/Impeller Cable
Service Interval:
After the first 2 hours—Inspect the
auger/impeller cable and adjust it if
necessary.
Yearly—Inspect the auger/impeller cable and
adjust or replace it if necessary.
1.
Loosen the jam nut.
2.
Engage the auger/impeller lever and hold it in
place (
g001013
Figure 34
18