Hydraulic System
Maintenance
Hydraulic Fluid
Specification
Preferred fluid:
Toro Hypr-Oil 500
Optional fluid:
15W-50 API rating CI-4/CF hydraulic
fluid
Checking the Hydraulic
Fluid Level
Service Interval:
Before each use or daily
1.
Prepare the machine for maintenance; refer to
Preparing the Machine (page 49)
.
2.
Remove the knee pad; refer to
.
3.
Check the hydraulic fluid level in the tank (
Important:
When the hydraulic fluid level is
correct, it is between the full and add marks
on the fluid-level decal.
g313188
Figure 100
1.
Hydraulic tank
3.
Full mark (fluid-level decal)
2.
Cap
4.
Add mark (fluid-level
decal)
4.
If the hydraulic fluid level is low, perform the
following:
A.
Remove the cap (
B.
Add the specified hydraulic fluid until it is
level with the full mark on the fluid-level
decal (
); refer to
Specification (page 69)
.
C.
Install the cap (
5.
Install the knee pad; refer to
.
Changing the Hydraulic
Fluid and Filter
Service Interval:
After the first 100 hours
Every 500 hours/Yearly (whichever comes first)
Hydraulic fluid quantity:
2.4 L (2.5 US qt)
1.
Prepare the machine for maintenance; refer to
Preparing the Machine (page 49)
.
2.
Remove the knee pad; refer to
.
3.
Clean area around hydraulic filter and filter head
(
).
g313259
Figure 101
1.
Hydraulic filter and filter head
4.
Align a drain pan with a 3 L (3 US qt) or greater,
under the filter (
69