![Toro 30609 Operator'S Manual Download Page 39](http://html1.mh-extra.com/html/toro/30609/30609_operators-manual_1133227039.webp)
Engine Warning Messages—Soot Accumulation
Indication Level
Fault Code
Engine Power Rating
Recommended Action
Level 1: Engine
Warning
g213866
Figure 37
Check Engine
SPN 3719, FMI 16
The computer de-rates the
engine power to 85%
Perform a parked regeneration
as soon as possible; refer to
Parked Regeneration (page 43)
.
Level 2: Engine
Warning
g213867
Figure 38
Check Engine
SPN 3719, FMI 0
The computer de-rates the
engine power to 50%
Perform a recovery regeneration
as soon as possible; refer to
(page 46)
.
39