Maintenance Reminder Screens
The hour meter displays the number of engine
hours until either the engine oil or transmission oil
maintenance is due. When maintenance is due, the
smart controller/electronic depth control displays
flashing icons for an engine oil maintenance alert or
a transmission oil maintenance alert, and the LED
status light displays a steady red light.
•
A maintenance alert occurs when the maintenance
counter reaches zero.
•
If the service is not performed, the maintenance
counter displays time as negative hours to indicate
the number of hours past due for the service (up
to -500 hours).
•
The hour meter switches between the default
screen and the active alert screen.
•
If more than 1 alert is active, the display cycles
between the alerts in the order that they occurred
before cycling back to the default screen.
The maintenance alerts only display when the default
screen has been active for 2 seconds; however, if
the key is moved to the
START
position, the alerts
occur immediately. When the machine is aerating,
the alert screen does not display but the LED status
light remains a steady red.
Service Engine Reminder
The engine-oil service reminder (
) counts
down from the initial break-in service interval of 5
engine hours and then counts down from 100 hours
for each service interval thereafter.
g030960
Figure 22
Service Transmission Reminder
The transmission oil maintenance reminder (
) counts down from the initial break-in service
interval of 100 engine hours and then counts down
from 250 hours for each service interval thereafter.
g030965
Figure 23
Opening and Closing the
Fuel Shutoff Valve
Control fuel flow to the engine with the fuel shutoff
valve as follows:
•
To open the fuel-shutoff valve, fully rotate the
handle for the valve left.
•
To close the fuel-shutoff valve, fully rotate the
handle of the valve right.
g249775
Figure 24
1.
Fuel tank
3.
Fuel-shutoff valve (closed
position)
2.
Fuel-shutoff valve (open
position)
Starting the Engine
1.
Ensure that the motion-control levers in neutral
and the parking brake is engaged.
Note:
You must engage the park brake and
move the motion control levers to the neutral
position to start engine.
2.
Place the throttle midway between the S
LOW
and F
AST
positions.
21