Installing the Auxiliary Valve

1.

Apply thread-locking adhesive to the 3 bolts (M8) and
secure the auxiliary valve to the bracket as shown in
Figure 2.

Figure 2

1.

90-degree fittings

3.

Bolts (M8)

2.

Bracket

2.

Install the 2 fittings (90 degree, 1/2-inch male, 5/8-inch
male) onto the valve as shown in Figure 2.

Note:

Ensure that the fitting on the right side is

turned 25 degrees.

3.

Remove the bolts, washers, and nuts securing the lower
right side panel to the ROPS (Figure 3).

Figure 3

4.

Secure the auxiliary valve assembly to the ROPS using
the bolts, washers, and nuts removed in the previous
step as shown in Figure 3.

Installing the Directional Valve
Cover and Assembly

1.

Install the 3 clip nuts onto the new cover assembly as
shown in Figure 4.

Figure 4

1.

Bolts (M6)

3.

Cover

2.

Clip nuts

2.

Apply thread-locking adhesive to the 3 bolts (M6) and
secure the cover to the bulkhead mount as shown in
Figure 4.

3.

Install both of the 90-degree fittings (5/8-inch male,
male), the Tee fitting, and the 90-degree fitting
(5/8-inch male, 5/8-inch female) onto the directional
valve as shown in Figure 5.

Figure 5

1.

90-degree fitting (5/8-inch
male, 5/8-inch male)

4.

Valve nut

2.

90-degree fitting (5/8-inch
male, 5/8-inch female)

5.

Coil

3.

Tee fitting

6.

90-degree fitting (5/8-inch
male, male)

4.

Torque the fittings to 142 to 162 N-m (105 to 120 ft-lb).

5.

Install the 30-inch hose onto the lower 90-degree
fitting (5/8-inch male, male) (Figure 5).

6.

Loosen the valve nut and rotate the coil on the
directional valve 180 degrees (Figure 5).

3

 

Summary of Contents for 25445

Page 1: ... harm Safety and Instructional Decals Safety decals and instructions are easily visible to the operator and are located near any area of potential danger Replace any decal that is damaged or lost 125 6696 1 Rotate counterclockwise 4 Move right 2 Rotate clockwise 5 Lower the guard 3 Move left 6 Raise the guard 2014 The Toro Company 8111 Lyndale Avenue South Bloomington MN 55420 Register at www Toro...

Page 2: ...aulic hose 30 inches 1 Directional valve assembly 1 Bolts 5 16 inch 2 Washer 2 Install the directional valve cover and assembly Short Hydraulic tube 1 Long hydraulic tube 1 Hydraulic hose 24 inches 1 90 degree fitting 5 8 inch male 3 4 inch female 2 Decal 1 Cable ties 2 Install the hydraulic hoses and the decal Preparing the Machine 1 Move the machine to a level surface 2 Set the parking brake and...

Page 3: ...er and Assembly 1 Install the 3 clip nuts onto the new cover assembly as shown in Figure 4 Figure 4 1 Bolts M6 3 Cover 2 Clip nuts 2 Apply thread locking adhesive to the 3 bolts M6 and secure the cover to the bulkhead mount as shown in Figure 4 3 Install both of the 90 degree fittings 5 8 inch male male the Tee fitting and the 90 degree fitting 5 8 inch male 5 8 inch female onto the directional va...

Page 4: ...90 degree fitting 5 8 inch male 3 4 inch female 2 Install the short hydraulic tube from the 90 degree fitting on top of the directional valve assembly to the closest 90 degree fitting on the bulkhead assembly as shown in Figure 7 3 Connect the 30 inch hose previously installed on the bottom of the directional valve assembly to the outside 90 degree fitting on the auxiliary valve as shown in Figure...

Reviews: