![Toro 22302 Operator'S Manual Download Page 15](http://html1.mh-extra.com/html/toro/22302/22302_operators-manual_1131125015.webp)
Check Before Operating
13
Remove Debris From Machine
IMPORTANT: Operating the engine with a
blocked or plugged radiator will result in
engine damage from overheating.
1.
Park the machine on a level surface, lower the
loader arms and turn the ignition key to “OFF”
to stop the engine. Remove the key.
2.
Check for debris on the air filter pre–cleaner.
Wipe away debris before each use and/or during
use, if required.
3.
Debris can build up in the engine area. Clean
any debris build–up with a brush or blower
before each use.
4.
From the front side of the radiator, either spray
the radiator with a hose or blow with compressed
air.
IMPORTANT: It is preferable to blow dirt
out, rather than washing it out. If water is
used, keep it away from electrical items.
IMPORTANT: DO NOT HIGH–PRESSURE
WASH. High–pressure washing can damage
the electrical system or deplete grease.
Check Hydraulic Fluid
Check the hydraulic fluid level before engine is first
started and after every 25 operating hours.
Fluid Type: Mobil Fluid 424 (ISO 46) or equivalent
anti–wear hydraulic fluid.
IMPORTANT: Use only group 1 hydraulic
oils specified. Other fluids could cause system
damage.
Group 1 Hydraulic Fluid (Recommended for
ambient temperatures consistently below 100
F.):
•
ISO type 46/68 anti–wear hydraulic fluid
•
Mobil
Mobil Fluid 424
Amoco
Amoco 1000
International Harvester
Hy–Tran
Texaco
TDH
Shell
Donax TD
Union OIl
Hydraulic/Tractor Fluid
Chevron
Tractor Hydraulic Fluid
BP Oil
BP HYD TF
Boron OIl
Eldoran UTH
Exxon
Torque Fluid
Conoco
Power–Tran 3
Kendall
Hyken 052
Phillips
HG Fluid
Note:
The fluids within this group are
interchangeable.
Hydraulic Tank Capacity: 15 gal. (56 l)
1.
Position machine on a level surface, lower the
loader arms and stop the engine.
2.
Clean area around filler neck of hydraulic tank.
3.
Remove cap from filler neck and check fluid
level. Fluid level should be up to green mark on
dipstick.
4.
If level is low, add enough fluid to raise to
proper level.
5.
Install cap on filler neck.