Toro 04730 Installation Instructions Manual Download Page 3

g016172

Figure 2

1.

Console arm frame

3.

Threaded ring

2.

Audio alarm

7.

Connect the audio alarm to the main wire
harness (gasoline model only) or to the kit wire
harness (diesel model only).

8.

If your machine is equipped with an overflow
hose, loosen the worm-drive clamps and remove
the overflow hose (

Figure 3

).

Note:

Discard the overflow hose and

worm-drive clamps.

g236811

Figure 3

1.

Worm-drive clamp

2.

Overflow hose

9.

Remove the 4 bolts, washers, spacers, and
rubber washers that secure the tank cover to
the main hydraulic tank.

Note:

Save the bolts, spacers, and washers

for securing the leak detector tank to the main
hydraulic tank later.

10.

Remove the tank cover from the main hydraulic
tank.

11.

Remove the plug from the hydraulic tank (if
equipped); refer to

Figure 4

.

g236699

Figure 4

1.

Plug

2.

Spout

12.

Insert the spout into the rubber grommet (

Figure

4

).

3

Installing the Leak Detector
Tank

Parts needed for this procedure:

1

Leak detector tank

1

Oil level sensor

1

O-ring

1

Valve hose

1

Tank valve hose

2

Hex-head bolt (1/4 x 2 inches)

1

Shield bracket

4

Hose clamp

1

Solenoid valve assembly

1

Straight fitting

2

90° hydraulic fitting

1

90° hydraulic fitting (beaded)

1

Delay timer (diesel model only)

1

Screw (5/8 inch)

1

Locknut

1

Oil level cover (diesel model only)

1

Oil level cover (gasoline model only)

1

Overflow hose

2

Worm-drive clamp

Procedure

1.

Find the appropriate oil-level cover for your
machine from loose parts.

3

 

Summary of Contents for 04730

Page 1: ...s 1 Cable tie 8 Indicator light 1 Audio alarm 1 2 Spout 1 Prepare to install the leak detector tank Leak detector tank 1 Oil level sensor 1 O ring 1 Valve hose 1 Tank valve hose 1 Hex head bolt 1 4 x...

Page 2: ...indicator and alarm leads in the console arm following the main wire harness under the seat to the other side of the machine and then behind the seat along the left hand rail so that the oil level se...

Page 3: ...main hydraulic tank later 10 Remove the tank cover from the main hydraulic tank 11 Remove the plug from the hydraulic tank if equipped refer to Figure 4 g236699 Figure 4 1 Plug 2 Spout 12 Insert the...

Page 4: ...ng to the main hydraulic tank Figure 7 g018539 Figure 7 1 Insert the 90 beaded hydraulic fitting here 4 Oil level cover 2 Shield bracket 5 Solenoid valve assembly 3 Hex head bolt 6 Install 1 end of th...

Page 5: ...in hydraulic tank Figure 9 g016177 Figure 9 1 Remove plug from main hydraulic tank here 2 Indicator arrow on nut 2 19 Slide the O ring onto the hydraulic oil level sensor and install the sensor into t...

Page 6: ...acteristics of your leak detector tank as follows If your leak detector tank has a sight window Fill the leak detector tank with hydraulic fluid until the fluid level is at the middle of the sight win...

Page 7: ...tank when you turn off the ignition switch g229108 Figure 13 Before Starting fluid cold 1 Filler plug 5 Warning buzzer no sound 2 Filler neck 6 Fluid level cold 3 Overflow tube 7 Solenoid return valv...

Page 8: ...eservoir is reduced by 118 to 177 ml 4 to 6 fl oz due to contraction of the fluid by cooling If the alarm sounds turn off the machine as quickly as possible and inspect it for leaks If the alarm sound...