Procedure
Description
Qty.
Use
Plug
1
4
Dipstick
1
Complete the leak detector tank
installation.
5
No parts required
–
Ensure that the leak detector is
operating correctly.
1
Preparing the Machine
No Parts Required
Procedure
1.
Park the machine on a level surface.
2.
Engage the parking brake.
3.
Shut off the engine and remove the key.
4.
Allow the engine to cool.
5.
Disconnect the battery; refer to your machine
Operator’s Manual
.
2
Preparing to Install the
Leak Detector Tank
Parts needed for this procedure:
1
Wire harness
8
Cable tie
1
Indicator light
1
Audio alarm
1
Spout
Procedure
1.
Remove the hex-head screws that secure the
console arm cover and remove the cover.
Note:
Save the screws for securing the console
arm cover later.
2.
Route the wire harness by positioning the light
indicator and alarm leads in the console arm,
following the main wire harness under the seat
to the other side of the machine, and then
behind the seat along the left-hand rail, so that
the oil level sensor and solenoid valve leads are
near the main hydraulic tank (diesel model only).
Refer to
for an overview of the
wire-harness position and the connector
locations.
g237783
Figure 1
Several parts removed from the machine for clarity.
1.
Indicator light connector
3.
Leak detector
solenoid/switch
connectors
2.
Audio alarm connector
4.
Time delay connector
3.
Use cable ties to secure the wire harness to the
main wire harness and frame members away
from any hot or moving parts (for diesel model
only).
4.
Remove the plug on the console arm panel and
insert the indicator light.
5.
Connect the indicator-light connector to the main
wire harness (gasoline model only) or to the kit
wire harness (diesel model only).
6.
Install the audio alarm into the console arm
frame (
).
2