background image

INTRODUCTION 

Thank you for choosing Tornado Industrial Vacuum Cleaner, a high-quality product 

based on the newest state-of-the-art technology. We hope that this device will be 

to your satisfaction and meet your expectations. We are continuously striving to 

improve our products in our product segment and will continue to supply the 

market with new equipment. 

 

 

 

NOTICE! 

1.These instructions are only for TIV2000 Dust Extractors. 

 

2.  TIV2000  Dust Extractors are designed to clean construction areas and be connected to 

small and medium machines such as drills, grinders etc. The machine is suitable for picking up 

dry, non-flammable dust and debris in and indoor environment. It is not suitable for picking up 

liquids. 

   

3. Please pay particular attention to the safety regulations and safety instructions 

 

4. Read the complete instruction manual before using. 

 

5. All spare parts and accessories used with this device must be those specified by Tornado. 

 

6. Check before and after use that all the switches are in OFF position.   

 

Environmental protection   

The packaging material can be recycled. Please do not throw the packaging material into 

household waste; please send it for recycling. 

 

Old devices contain valuable materials that can be recycled; these should be sent for 

recycling. Batteries, oil, and similar substances must not enter the environment. Please dispose 

of your old devices using appropriate collection systems. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for TIV2000

Page 1: ...ng up dry non flammable dust and debris in and indoor environment It is not suitable for picking up liquids 3 Please pay particular attention to the safety regulations and safety instructions 4 Read the complete instruction manual before using 5 All spare parts and accessories used with this device must be those specified by Tornado 6 Check before and after use that all the switches are in OFF pos...

Page 2: ...capabilities or lack of experience and knowledge Do not use with damaged cord or plug If the machine is not working as it should has been dropped damaged left outdoors or dropped in water Make sure it is repaired by a qualified person Do not pull or carry by cord use cord as handle close a door on cord or pull cord around sharp edges or corners Do not run the machine over cord Keep cord away from ...

Page 3: ...the label before using Replace label if it is missing becomes damaged or illegible Failure to follow this warning label may result in fire electric shock or injury 2 UNPACKING When unpacking the machine please check that the following accessories are included The hose with end fittings Wand Floor brush If any of the above mentioned parts are missing please contact your local distributor or our sal...

Page 4: ...into the plastic bag The filter cleaning process is not completed before it is clear that the dust inside the tank has fallen down into the collection bag In some extreme cases the adhesive ability of the dust must be broken manually This can be done by hitting the dust through the bag or tapping the tank using i e a rubber hammer 4 HEIGHT ADJUSTMENT Optional TIV2000 TIV3000 WITH HEIGHT ADJUSTMENT...

Page 5: ...l be divided into plastic bags using the zip ties attached with the machine To assemble a new continuous bag Release the belt holding the last bag Remove the holder put in a new bag pull out the inner end upwards Assemble the holder on to the machine and strap the opening facing upwards with the belt Pull down the outside end and close it using a zip tie All dust extractors can be used with contin...

Page 6: ... must be regarded as contaminated and be treated thereafter If possible use a special suitable room Proper personnel protective equipment must be used Dust can be spread when the coarse filter and the absolute filter are replaced that can be hazardous to health Accordingly the user should wear protective glasses protective gloves and a breathing mask conforming to protection class FFP3 All parts w...

Page 7: ...Issue Cause Solution Motor doesn t start No Power Plug in machine Cable defective Replace cable Switch defective Replace switch Motor stops immediately after starting Shortcut in cable machine Order service Motor runs but there is no suction Hose not connected Connect hose Hose clogged blocked Clean hose No dust collection bag Fit dust collection system Motor runs but poor suction Hole in hose Rep...

Page 8: ...mx D50 USCS inch 24 X2 24 X2 Inlet Metric mm 70 70 USCS inch 2 8 2 8 Pre filter EN 779 F8 1μm 99 5 99 5 Pre filter area Metric m2 3 3 USCS ft2 32 32 HEPA filter EN1833 H13 0 3μm 99 99 99 99 H13 HEPA filter area Metric m2 2 4 2 4 USCS ft2 26 26 Dust collection system Type Continuous folding bag Continuous folding bag Dimensions L W H Metric mm 570x710x1270 570x710x1270 USCS inch 22 4x28x50 22 4x28x...

Page 9: ...it 1 TIV2000 dust extractor 1 PC 2 S8046 D50 S wands 2PCS SET 1 SET 3 C2031 D70 50 reducer 1 PC 4 S8008 D50 EVA anti static hose 7 5 Meter 5 S8006 D50 hose cuff 2 PC 6 S8045 D50 floor brush 1 PC TIV2000 120V TIV2000 230V Packing list ...

Page 10: ...round tube pulley 8 9 C2101 TIV pulley fixed plate 2 10 C2083 Nylon cable tie storage container 1 11 C2096 TIV2000 slider bar lower bracket 1 12 C2140 TIV2000 left stand column 1 13 S0032 hexagon bolt 2 M10 60 14 S0045 Plain cushion 2 M10 15 S0015 locknut 2 M10 16 S9030 Universal wheels 2 3 Lockable 17 C2136 TIV2000 bed plate 1 18 S9011 Heavy dusty caster 2 8 19 S0033 hexagon bolt 2 M12 100 20 S00...

Page 11: ...TIV2000 120V TIV2000 230V Dustbin kit ...

Page 12: ... 8 M6 10 S0059 Holder kit 2 11 C2121 TIV2000 barrel 1 12 B0039 D70 inlet kit 1 17 C2092 Holder 1 18 S0023 Bolt 2 M6 35 19 C2090 Flap assembly kit 1 20 C2091 Balancing weight 6 21 C2084 Continuous bag holder packing 1 22 S0089 Nut 2 M8 15 23 S0090 Belt packing 1 24 S8035 Continuous folding bag 1 25 S8006 D50 anti static hose cuff 2 26 S8007 D50 EVA hose 2 D50 520mm 27 S8029 TIV2000 main filter 1 28...

Page 13: ...ity plug 1 3 1 5 8 meters length RVV 10A plug 240V S2006 Cable with electricity plug 1 3 2 0 8 meters length RVV US plug 110V 5 C1106 Baffle 1 6 C2128 TIV2000 engine cover front 1 7 C2131 TIV2000 engine over front 1 8 S9022 Vacuum meter 1 9 S1001 Switch 2 10 S1038 Hour counter 1 11 S0010 Bolt 20 M6 12 TIV2000 120V TIV2000 230V Engine kit ...

Page 14: ... absorption rubber ring 2 7 S1034 Single phase motor 1 240V 1000W S1035 Single phase motor 1 120V 1200W TS1100 S1036 Single phase motor 1 120V 1000W TS2100 S1037 Single phase motor 1 120V 800W TS3100 8 S0086 Screws 1 3 M6 76 5 9 C2123 TS motor fixed plate 1 10 S0087 Screws 2 3 M6 96 5 11 S9028 Soundproof sponge 1 D98 78 15 12 S9029 Filtering cotton 1 D78 8 TIV2000 motor package ...

Page 15: ...lideway 1 5 C2043 Inlet close door 1 6 S0076 Copper collision 4 7 C2022 Index plunger 1 8 C3021 70 outer inlet 1 9 S0013 Locknut 4 M6 10 S0013 Half round inner hexagon bolt 3 M6 35 11 S0022 Half round inner hexagon bolt 1 M6 20 12 S0024 hexagon bolt 1 M8 20 13 S0014 Locknut 1 M8 14 S0077 ball knob 1 M8 30 TIV2000 120V TIV2000 230V D70 inlet kit ...

Reviews: