background image

11

GENERAL PRECAUTIONS

  Do not use the machine for 

dry 

vacuuming.  This machine is not fitted

with a dry filter.

  Use defoamer in the recovery tank at all times to prevent damage to the

vacuum motor.

  Do not use water in excess of 140 degrees F (60 degrees C).

 Use only 

low foaming

 carpet and upholstery cleaners and defoamers

intended for machines of this type.  Do not use dyes, bleaches,
ammonia or other additives.  The use of powdered cleaning solution if
not diluted properly may result in the intake screen clogging or damage
to the pump.

  Do not expose machine to freezing temperatures.

  Do not attempt to repair warranted machines.  All repairs must be done

by a qualified and authorized repair center.  Non warranted repairs will
be billed back to the owner of the unit.

  Do not use any replacement parts except those specified in the parts

list. Unauthorized parts will void the warranty and could cause the unit
not to function properly.

REQUIRED CLEANING CHEMICALS

Use only low foam cleaning chemicals that are designed for carpet and
upholstery extraction.

   General carpet and upholstery extraction cleaner added to the solution

tank.

   Traffic lane pre-spray usually applied with a hand or pump-up sprayer.

   Spotter used with a hand sprayer.

   Defoamer only goes into the recovery tank.

CAUTION: 

 Use as directed.  Do not over-use the cleaning chemicals.

EXTENSION CORD

If an extension cord is used, the wire size must be a least one size larger
than the power cord on the machine.  The ProSpot is equipped with a 25’
18-3 power cord.

FAILURE TO COMPLY WITH THE ABOVE WARNING INSTRUCTIONS
WILL VOID THE WARRANTY.

Summary of Contents for PS Series 64230

Page 1: ...708 867 5100 FAX 708 867 6968 www tornadovac com Tornado Operation Maintenance Manual For Commercial Use Only The PS Series of Carpet Spotters Series F Catalog No 64220 98220 115v 60Hz 98221 230v 50H...

Page 2: ...2 NOTES...

Page 3: ...SI 55 PSI VACUUM 94 CFM 84 H 2 O 82 CFM 68 H 2 O 94 CFM 84 H 2 O CAPACITY 2 Gal 2 Gal 7 6l 2 Gal VOLTS 115V 230V 115V AMPS 8 4 8 CERTIFICATION This product conforms to ANSI UL Standard 561 and is cert...

Page 4: ...er cleaning equipment 1 2 Warranties do not cover components subject to normal wear or abuse and misuse and have other limitations not specified here For full details contact your Authorized Tornado D...

Page 5: ...d left outdoors or dropped into water return it to a service center 7 Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Do not run machi...

Page 6: ...pareil par le cordon Ne pas utiliser le cordon comme une poign e le coincer dans l embrasure d une porte ou l appuyer contre des ar tes vives ou des coins Ne pas faire rouler l appareil sur le cordon...

Page 7: ...ance if it will not fit the outlet have a proper outlet installed by a qualified electrician This appliance is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug i...

Page 8: ...e ins r e dans la prise faire installer une prise ad quate par une lectricien qualifi CROQUIS A CROQUIS B CROQUIS C Cet appareil est destin un circuit de 120 V et est muni d une fiche de terre semblab...

Page 9: ...ure years of satisfactory service if operated and maintained according to recommendations in the manual If additional information is needed please contact your local distributor or write to TORNADO IN...

Page 10: ...repair and warranty work is not normally handled at the factory WARNING The machine was designed for use in spot cleaning on carpeted floors and for upholstery extraction applications as per instruct...

Page 11: ...Non warranted repairs will be billed back to the owner of the unit Do not use any replacement parts except those specified in the parts list Unauthorized parts will void the warranty and could cause t...

Page 12: ...our in a non foaming cleaning concentrate to the proper dilution noted on the container Be sure that the vacuum motor foam filter is in place located on top of the solution tank 3 Place the recovery t...

Page 13: ...If the carpet is loose heavily soiled stained spotted or badly worn point this out to the person in charge Locate an inconspicuous spot on the area to be cleaned Test carpet for colorfastness before p...

Page 14: ...leaning solution noted by streaking or no solution flow turn off the machine and drain the recovery tank Refill solution tank and continue cleaning To decrease drying time go over the carpet and or fu...

Page 15: ...is highly recommended that once a month you flush the ProSpot out with a 8 to 1 ratio of water to white vinegar or anti browning solution through the extractor This will help to prevent the build up...

Page 16: ...W KEEPER 19504 2 20 WHEEL 6 DIA X 1 1 4 BLACK W BLK HUB 19505 2 21 SPACER 5 16 DIA 19506 2 22 NUT HEX LOCK NYL INS 5 16 18 19513 2 23 ASSEMBLY VACUUM STACK FLOAT CAGE 19516 1 24 SCREEN VAC MOTOR INTA...

Page 17: ...17 ES SERIES CARPET SPOTTERS 64230 98220 98221 MAIN ASSEMBLY EXPLODED VIEW REF DRAWING 98221...

Page 18: ...S 64230 98220 98221 HANDLE ASS Y REF DWG 31215 ITEM NO DESCRIPTION PART NO QTY 1 Washer Lock E T 10 01713 4 2 Screw Phillips Pan Head Machine 10 24 X 1 000 19617 4 3 Bracket Pump Mounting For Referenc...

Page 19: ...POTTERS 64230 98220 98221 ASS Y VAC PRESSURE HOSE REF DWG 30744 ITEM NO DESCRIPTION PART NO QTY 1 Suction Hose 8 30735 19529 1 2 Solution Hose Ass y 30801 19639 19535 1 3 Tool Utility 30857 1 4 Plasti...

Page 20: ...ASSEMBLY POWER CORD 115V SPOTTER INCLUDES ITEM 4 19499 1 7 ASSEMBLY POWER CORD 230V SPOTTER 19500 1 8 TERMINAL Q D FEMALE 1 4 X 22 18GA FUL INS 19503 1 9 LEAD 18 GA X 12 GREEN 19536 1 10 LEAD 16 GA X...

Page 21: ...NCLUDES ITEM 5 ON EACH END 19538 1 11 5 16 NON INSOLATED PIGGY BACK FEMALE END CONNECTOR S 15391 2 12 LEAD 14 GA X 12 GREEN FROM MOTOR INCLUDES ITEM 5 ON ONE END AND ITEM 13 ON THE OTHER END 80673 1 1...

Page 22: ...22...