GENERAL PRECAUTIONS

x

  Make sure the machine is plugged into an electrical outlet with the same voltage and frequency

rating as shown on the nameplate of the machine.  Do not attempt to plug a 115-volt machine in
a 230-volt outlet.

x

  Disconnect power cord from the outlet before attempting maintenance or repair work.  Do not

leave machine connected to an electrical outlet when unattended.

x

  Don’t abuse power cord.  Never pull the machine by the cord or yank plug from the receptacle.  If

this machine is operated on a wet carpet a potential shock hazard can be caused by a damaged
cord.  Replace a damaged cord immediately.

x

  Do not immerse this machine in standing water.  Such use can cause electrical shock.

x

  Do not use volatile substances such as gasoline or kerosene in the machine, on or near the

surface to be cleaned.  The use of such materials could cause an explosion and fire.

x

  If an extension cord is necessary, use a 3 conductor grounding cord, 12-gauge wire to prevent

motor burnout, overheating of the wiring.

x

  To avoid electrical shock, do not expose to rain and store indoors.

WARNING

The machine was designed for use on carpeted floors as per instructions

and recommendations written in this manual.  Any deviation from its proper use or purpose
and the consequential damage that may occur is the sole responsibility of the end user.

x

  Do not use the machine for 

dry

 vacuuming.  This machine is not fitted with a dry filter.

x

  Use defoamer in the recovery tank at all times to prevent damaging the vacuum motor.

x

  Do not use water in excess of 140 degrees F (62 degrees C).

x

  Use only commercially available 

low

 foaming carpet cleaners and defoamers intended for

machines of this type.  Do not use dyes, bleaches, ammonia or other additives.  The use of
powdered cleaning solution if not diluted properly may result in the intake screen clogging or
damage to the pump.

x

  Do not expose machine to freezing temperatures.

x

  Do not attempt to repair warranted machines.  All repairs must be done by a qualified and

authorized repair center.  Non-warranted repairs will be billed back to the owner of the unit.

x

  Do not use any replacement parts except those specified in the parts list.  Unauthorized parts will

void the warranty and could cause the unit not to function properly.

FAILURE TO COMPLY WITH THE ABOVE WARNING INSTRUCTIONS

WILL VOID THE WARRANTY

Summary of Contents for Marathon 1200

Page 1: ...67 6968 www tornadovac com Tornado Operations Maintenance Manual For Commercial Use Only Marathon Carpet Rinser Dryers Models 800 1200 MODEL NO 98166 98168 115V 60Hz For parts list see L2669LFP Effect...

Page 2: ...NOTES...

Page 3: ...0 MODEL NO 98166 98168 VOLTS 115 115 SERIES F F ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE TABLE OF CONTENTS Warranty 4 Safety Instructions 5 Preparation and General Instructions 6 Cleaning T...

Page 4: ...KMR 1250 and KMR 1700 are 24 months parts 6 months labor OR 1000 hours of operation whichever comes first Warranties on the 75 140 90 140 are 24 months parts 12 months labor OR 1 000 hours of operati...

Page 5: ...ed left outdoors or dropped into water return it to a service center 6 Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Do not run mach...

Page 6: ...product improvement we reserve the right to make changes at any time without notice This machine was shipped with window washer antifreeze during the winter months in the solution line system to prot...

Page 7: ...ore indoors WARNING The machine was designed for use on carpeted floors as per instructions and recommendations written in this manual Any deviation from its proper use or purpose and the consequentia...

Page 8: ...electrician or service person if you are in doubt as to whether the outlet is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet in...

Page 9: ...dry on the carpet x Identify the type of carpet fiber to be cleaned Most commercial carpet fibers in use are nylon or acrylic based Best results in cleaning would be obtained if hot water is used to...

Page 10: ...STABLE PIVOT MOUNT Q BRUSH 17 LONG Q BRUSH SPEED 900 RPM Q SOLUTION PUMP 100 PSI DIAPHRAGM STYLE Q SOLUTION CAPACITY MARATHON 800 8 GAL MARATHON 1200 12 GAL Q RECOVERY CAPACITY MARATHON 800 10 GAL MAR...

Page 11: ...a 12 gage extension cord as needed WARNING To avoid serious injury Plug into a grounded earth outlet only Do not use an adapter or remove ground pin on plug Do not use a damaged cord 6 Activate the va...

Page 12: ...peting x If the spray jets drip after the pump is turned off the solenoid valve may need to be cleaned x Once a month inspect all electrical cables hoses filters and connections in the Marathon 800 12...

Page 13: ...otor runs but poor suction Remove debris from vac shoe Recovery tank too full drain tank Remove debris from suction hose Call Service Vacuum motor will not run Activate vacuum switch Check for loose w...