background image

4

IMPORTANT SAFETY INSTRUCTIONS

FOR COMMERCIAL USE

WHEN USING AN ELECTRICAL APPLIANCE, BASIC PRECAUTIONS SHOULD

ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING:

READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:

1.        Do not leave machine when plugged in.  Unplug from outlet when not in use and

before servicing.

2.       Use indoors only. Do not use outdoors and do not expose to rain.

3.        Do not allow to be used as a toy.  Close attention is necessary when used by or

near children.

4.        Use only as described in this manual.  Use only manufacturer’s recommended

attachments.

5.        Do not use with damaged cord or plug.  If machine is not working as it should, has

been dropped, damaged, left outdoors, or dropped into water, return it to a service
center.

6.        Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord

around sharp edges or corners.  Do not run machine over cord.  Keep cord away
from heated surfaces.

7.        Do not unplug by pulling on cord.  To unplug, grasp the plug not the cord.

8.        Do not handle plug or machine with wet hands.

9.        Do not put any object into openings.  Do not use with any opening blocked; keep

free of dust, lint, hair, and anything that may reduce air flow.

10.      Keep hair, loose clothing, fingers, and all parts of body away from openings and

moving parts.

11.      Turn off all controls before unplugging.

12.      Use extra care when cleaning on stairs.

13.      Do not use to pick up flammable or combustible liquids, such as gasoline or use in

areas where they may be present.

14.      Connect to a properly grounded outlet only. See Grounding Instructions.

SAVE THESE INSTRUCTIONS

Summary of Contents for 98190

Page 1: ...CAGO IL 60706 708 867 5100 FAX 708 867 6968 www tornadovac com Tornado Operation Maintenance Manual For Commercial Use Only Marathon 2000 Forward Only Extractor CATALOG NO 98190 115V 60 HZ L8190CF 6 0...

Page 2: ...2 NOTES...

Page 3: ...Tornado Distributor Service Center or the Tornado Technical Service Department Tornado sales and service representatives are not authorized to waive or alter the terms of this warranty or to increase...

Page 4: ...ed left outdoors or dropped into water return it to a service center 6 Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Do not run mach...

Page 5: ...AX 708 867 6968 All information and specifications printed in the manual and parts list are current at the time of printing However because of Breuer s policy of continual product improvement we reser...

Page 6: ...ore indoors WARNING The machine was designed for use on carpeted floors as per instructions and recommendations written in this manual Any deviation from its proper use or purpose and the consequentia...

Page 7: ...a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a pro...

Page 8: ...le EXTENSION CORD If an extension cord is used the wire size must be at least one size larger 12 3 than the power cord on the machine REQUIRED CLEANING CHEMICALS Use only commercial low foam cleaning...

Page 9: ...to dry on the carpet Identify the type of carpet fiber to be cleaned Most commercial carpet fibers in use are nylon or acrylic based Best results in cleaning would be obtained if hot water is used to...

Page 10: ...UUM SHOE 22 WIDE CAST ALUMINUM ADJUSTABLE FLOATING ARM Q BRUSH 19 LONG Q BRUSH SPEED HP 1000 RPM 1 4 HP Q SOLUTION PUMP 100 PSI DIAPHRAGM STYLE Q SOLUTION CAPACITY 20 GALLONS Q RECOVERY CAPACITY 20 GA...

Page 11: ...glide easily across the floor when pushed forward without power WARNING In order to avoid injury it is recommended that the extractor be pulled in the reverse direction without power in emergency situ...

Page 12: ...e manual release lever and allow the brush assembly to rest on the floor The height of the suction nozzle may need to be adjusted using the turn knob 7 Activate the vacuum motor switch 8 Activate the...

Page 13: ...h a 8 to 1 ratio of water to white vinegar or anti browning solution through the extractor This will help to prevent the build up of alkaline residue If the spray jets become clogged remove and wash t...

Page 14: ...gallon of pre mixed window washer antifreeze into the tank The windshield washer fluid must not be diluted with water or solution already in the tank Turn on the brush switch and press the spray swit...

Page 15: ...ot Rotate Reset Circuit Breaker Activate Brush Switch Check For Loose Wiring Call Service Poor Water Spray Spray Jets Clogged Remove Spray Bar and Clean Spray Jets Check Pump Remove Spray Bar And Chec...

Page 16: ...16 MAIN ASSEMBLY...

Page 17: ...17 UPPER TANK ASSEMBLY REF 30642...

Page 18: ...18 UPPER TANK ASSEMBLY REF 30642...

Page 19: ...19 LOWER TANK ASSEMBLY REF 98190...

Page 20: ...20 LOWER TANK ASSEMBLY REF 98190...

Page 21: ...21 LOWER TANK ASSEMBLY REF 98190 BOTTOM VIEW BACK VIEW...

Page 22: ...22 CONTROL PANEL ASSEMBLY REF 30644 NOT SHOWN...

Page 23: ...23 CONTROL PANEL ASSEMBLY REF 30644...

Page 24: ...24 BRUSH ASSEMBLY REF 30643...

Page 25: ...FLAT HEAD MACHINE 10 24 X 19165 12 16 FITTING BRASS ADAPTER 1 8 NPT X 3 8 19189 1 17 SPACER 5 16 DELRIN 19190 1 18 WASHER PLAIN 328 19191 1 19 SCREW SLOTTED TRUSS HD MACHINE 3 8 16 X 3 4 19207 3 20 B...

Page 26: ...26 PUMP ASSEMBLY REF 30645...

Page 27: ...27 RECOVERY DOME ASSEMBLY REF 30646...

Page 28: ...28 WIRING DIAGRAM REF 30702...

Page 29: ...29 WIRING DIAGRAM REF 30702...

Reviews: