Inspection
Unpack and inspect your extractor for shipping damage. Each unit is tested and inspected prior to
shipping. For any concerns regarding shipping damage, contact your dealer immediately. All returns
must have a Return Authorization (RA) number.
Grounding Instructions
The extractor
MUST BE GROUNDED
. If the machine should stop working or malfunction, grounding
offers a path of least resistance for
electrical current, reducing the risk of
electrical shock. This
machine is equipped with a cord that has an equipment grounding conductor and a grounding plug.
The plug must be inserted into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances. Cutting off the ground wire or using a cord that is not
properly grounded will void the manufacturers warranty on this machine.
Safety
Warning - To reduce the risk of fire, electrical shock or Injury:
•
READ ALL INSTRUCTIONS BEFORE USING.
•
Use only as described in this manual.
•
Plug power cord Into the nearest outlet (20A preferred).
•
Never attempt any adjustments or repairs while the machine is plugged in.
•
Do not use outdoors, in standing water, or on wet surfaces.
•
Pay close attention when using unit near children.
•
Do not leave unit outdoors, or in extreme heat or cold. Harsh weather elements will damage
components and void warranty.
•
Lift using only the appropriate handles.
•
Always wear appropriate clothing and safety equipment when operating unit.
•
Keep all body parts, hair, and loose clothing away from openings and moving parts
•
Use extra care when cleaning on stairs. Do not move up or down stairs with fluid in the unit.
•
Use common sense to protect yourself and others from injury when using an extractor.
Warnings
•
Do
not
run the pump without water in the solution tank.
•
Do not use hot liquids in the solution tank.
•
Do not pick up combustible or flammable materials.
•
Do not use your extractor with a damaged cord.
•
Do not operate without the float shut-off assembly in place.
Precautions
•
Do not run the pump dry. This will void the manufacturer warranty.
•
Do not run hot fluids through the pump. This can cause pump cavitation and will void the warranty.
This is a water-cooled pump.
•
Always be sure the solution tank and hoses and filters are clear of debris. Running the pump with
clogged filters or hoses can cause pump damage.
•
Replace any damaged cords or hoses before use.
Chemical Use
•
Only use chemicals approved for use with extraction.
•
Keep the appropriate MSDS sheets on
hand at all times.
•
Flush the solution pump with clean water after each use to extend the life of the pump.
Summary of Contents for 2-100 H Professional
Page 6: ...ACCESSORIES FOR ALL MODELS...
Page 9: ......
Page 10: ...FRONT VIEW CLOSE UP TOP RECOVERY TANK...
Page 11: ...RECOVERY TANK PARTS...
Page 12: ...RECOVERY TANK INTERNAL VIEW...
Page 13: ...SOLUTION TANK...
Page 14: ...SIDE VIEW BOTTOM ASSEMBLY...
Page 15: ...REAR VIEW BOTTOM ASSEMBLY...
Page 16: ...CONNECTIONS SOLUTION TANK...
Page 17: ...INTERNAL VIEW BOTTOM ASSEMBLY...
Page 18: ...INTERNAL VIEW BOTTOM ASSEMBLY VAC MOTORS...
Page 19: ...INTERNAL VIEW BOTTOM ASSEMBLY VAC HOSE CLAMP...
Page 20: ......
Page 21: ...PUMP W FITTINGS...
Page 22: ...PUMP HEATING ELEMENT...
Page 23: ...HEATING ELEMENT W FITTINGS ELECTRICAL PLUMBING SYSTEM...
Page 24: ......