Summary of Contents for Smart Switch Box

Page 1: ...www smstork com valve automation JANUARY 2019 PLEASE READ THE INSTRUCTİONS BEFORE USE SMART SWITCH BOX USER S MANUAL ...

Page 2: ...MENU AND FUNCTIONS 10 a Opening 10 b Language Selection 10 c Monitoring Screen 11 d Settings 12 e Partial Stroke Test PST 12 f Counter reset 13 g Changing Product ID Password 13 h Manual Control 14 i Temperature Settings 15 j Warnings 15 k Factory Settings 16 4 SSB INSTALLATION 17 a Mounting of SSB to Actuator 17 b Electrical Connection 18 7 SSB SPARE PARTS 18 8 PRODUCT TRANSPORTATION 19 9 WARRANT...

Page 3: ...f prolonged use it will notice and inform you of a possible fault condition without any fault Continuously measures the temperature value and warns if it is outside the temperature values you set Measures both opening and closing air pressures and gives warning of any air leakage With two different counters on the monitoring screen it shows how many times has been on and off from the first day and...

Page 4: ...gnated as SSB100 d Exploded Picture Status Indicator Electronic Control Board Switch Cam Proximity Switches Bracket Namur Valve Top Cover Lexan Screen Body Power Board Pressure Transmitters SMS TORK Endüstriyel Otomasyon Ürünleri San Tic Ltd Şti 4 valve automation ...

Page 5: ...h Details In order to get position in the smart switch box proximity sensors are used and mechanical switches are used for output The switch brand model and features used are as follows g Dimensions Model Hosense KW7 Switch Function Mechanical Single Pole Double Throw Certifications VDE RU IP65 Nominal Values 16 A 250 V Working Temperatures 25 C 125 C Model Pepper Fuchs NBB2 V3 E2 Switch Function ...

Page 6: ...ovatink com login After the entry all devices belonging to the company will be displayed on the map and in the list This screen also contains warning information for all devices The switch box of the valve to be controlled from the list is selected by double clicking Figure 2 User Login Screen SMS TORK Endüstriyel Otomasyon Ürünleri San Tic Ltd Şti 6 valve automation ...

Page 7: ...d on the control screen By clicking on the buttons opening closing and status monitoring is done The following information is displayed on the control screen Figure 4 Device ID number and valve position and command display screen Figure 3 Device List Screen www smstork com 7 valve automation ...

Page 8: ...umber of times made on off since the first use Counter 2 shows the counter values that can be reset Counter 2 value can be reset after confirmation from the confirmation screen after clicking the arrow on the counter 2 indicator On off time of the actuators are displayed in ms All warnings and faults that occur in the actuator are included in the warnings area Faults continue to remain as long as ...

Page 9: ...tings can be made Also status information is given with LEDs on the top of the screen visually The control method is described in detail in Chapter 3 c Control with Control Signal The smart switch box can send on or off command by applying 24 VDC voltage to the EXT_OPN and EXT_CLS terminals on the electronic board When 24 VDC is applied to the EXT_OPN terminal the valve will open and the valve wil...

Page 10: ...menus a Opening The TORK logo is opened when the SSB is energized For the first used language selection is queried Switches directly to the monitoring screen if it is not first use Caution If no key is pressed for 5 seconds while switching between menus the screen is automatically switched to the monitoring screen b Language Selection For the first time the language selection is queried In the nex...

Page 11: ...m with the connection of the GSM antenna S1 Counter 1 shows how many times the device has switched on and off from the first time it is used It cannot be reset S2 Counter 2 shows how many times the device has switched on after it has been reset A reset can be made in the settings menu P1 Indicates air pressure in device s port A P2 Indicates air pressure in device s port B Displays the position of...

Page 12: ...ng task is performed or not The closing time is measured and gives a fault indication if the value is outside of the specified limit In the next step pressure values are measured from two channels After waiting for 10 sec the pressure values are measured again In this way it is determined whether there is any air leakage The valve opens again The opening time is measured and gives a fault indicati...

Page 13: ...menu for resetting Resetting is performed by answering the query with the OK button on the counter reset tab Figure 21 PST test result screen Figure 22 PST test result screen Figure 23 Counter reset screen Figure 24 Counter reset result screen g Product ID Change password To change the ID information of the device and to control manually password must be entered The first device password is given ...

Page 14: ... entered after selection After entering the correct password enter the new product ID and press OK button Product ID information can be verified from the monitoring screen h Manual Control For valve maintenance or any other reason which needed to be controlled manually it can be controlled manually When switched to the manual control product control is not allowed in any way except buttons In othe...

Page 15: ...pdated In this case the Temperature Settings tab should be selected in the Settings screen Select one of the lower and upper limit tabs using the arrow keys Press OK to select the limit value screen After the selection is made it is set to the desired value by using direction buttons Press OK to save When the measured temperature values are outside the specified values it starts to give warning j ...

Page 16: ...han the setting closing time OPEN TIME OVER If the opening time is longer than the set opening time PST TEST FAIL If any error is encountered when performing a partial stroke test CARE WARNING Before the malfunction occurred but high possibility to occur malfunction SERVICE REQUIRED Starts warning when exceed specified number of on off or when general maintenance is required at specified periods k...

Page 17: ...Check the position of the actuator shaft and the position indicator before installing the switch box on the actuator Mount the switch box to actuator with its bracket and screws Figure 34 Mounting of SSB to actuator www smstork com 17 valve automation ...

Page 18: ...t can switch AC DC voltages On request mechanical can be replaced with proximity sensors 7 SSB SPARE PARTS SSB s spare parts Electronic Control Cards Position Indicators Antenna Air gland Figure 35 SSB electrical connection schema SMS TORK Endüstriyel Otomasyon Ürünleri San Tic Ltd Şti 18 valve automation ...

Page 19: ... changed during the warranty condition is limited to the remaining warranty period of the purchased products 5 Free repair and product exchange obligations will be annulled under the following conditions a If the product becomes faulty due to use contrary to the terms or conditions stated in the user guide b If the product serial number has been altered or removed c The warranty labels have been d...

Page 20: ...SECTOR LEADER WITH 30 YEARS EXPERIENCE SMS TORK Endüstriyel Otomasyon Ürünleri San Tic Ltd Şti ...

Page 21: ...www smstork com ...

Page 22: ...anbul TURKEY P 90 216 364 34 05 F 90 216 364 37 57 FACTORY İMES O S B S Cad No 5 Çerkesli Dilovası KOCAELİ TURKEY P 90 262 290 20 20 F 90 262 290 20 21 SMS TORK Endüstriyel Otomasyon Ürünleri San Tic Ltd Şti www smstork com SMSTORK sms tork KUL45 SSB100 08 02 2019 REV 00 EN ...