2. Identity

The GA21 gas alarm detector is a device that detects explosive gases in the environment. 1.5 minutes 
after the supply voltage is applied, the sensor warms up and reaches the normal detection level. It is not 
recommended to test with any gas before this period expires. If the gas leakage level is above the set 
limit value, the device gives an alarm. As long as the gas leakage is above the limit level, the device 
continues to alarm. When the gas leakage falls below the set limit level, it automatically shuts down the 
alarm and relays and cuts off the energy of the connected systems.

If the gas valve is to be closed or the gas to be evacuated from the environment under alarm conditions, 
the desired system can be controlled by using the output relays of the gas alarm device. Analog output 
signals in the device PLC etc. It can be controlled by connecting to systems such as By changing the 
sensor head, different gases can be detected. It is a general-purpose, simple and easy-to-use device that 
can output mA or volts, control the systems connected to the output relays, and give audible and visual 
warnings.

Developed considering the needs of the user, the GA21 gas alarm detector has a structure that simplifies 
and strengthens the communication between the user and the device. The device contains 2 output 
control relays, 1 gas level output (mA and Volt), 1 buzzer (audio warning), Zero, Span and offset (%LEL 
adjustment) trimpots and electronic board.

2.1. Description of the device

GA21 gas alarm detector is connected to the level signal output and connected to intelligent and 
controllable systems (PLC etc.) (0-20, 4-20, 0-10, 2-10 mA, 0-5, 1-5, 0-10, 2 -10 VDC) sends analog 
signals. It is a product that aims to warn the user with sound and light by controlling the gas level in the 
environment, to send signals to the connected systems, to control, to use the systems it controls safely 
and to prevent possible dangers.

2.2.  Intended use of the device

• Long life

• Being ExProof

• Less energy consumption

• Modular design structure

• Easy assembly and disassembly

• Ease of adjustment and flexible operation

• Robust and lightweight construction

• Informing the user with the alarm

2.3. Reasons for use

Summary of Contents for GA 21

Page 1: ...valve automation GA 21 Gas Alarm Device User s Manual www smstork com PLEASE READ THE INSTRUCTIONS BEFORE USED JANUARY 2022...

Page 2: ...m Detector It cannot be used as a reference for any other device The right to make changes is reserved Contains information for installation commissioning and maintenance personnel 1 Safety instructio...

Page 3: ...s 4 1 Possible malfunctions and solutions 4 2 Power cut 4 3 Making the Settings 4 4 Installation Assembly 5 Electrical Connections 5 1 Connection of GA21 gas alarm detector to GAP30 gas alarm control...

Page 4: ...pose a hazard to the application or damage the installation The manufacturer cannot be held responsible for any consequential damages This risk is entirely with the user Care should be taken in cases...

Page 5: ...available The user must have received the necessary training and knowledge about fire extinguishing After making sure that the device connections are made correctly and completely the device should b...

Page 6: ...e commissioning the device make the necessary settings on the device make sure that it detects gas that the output control relays work that the buzzer audible warning and signal output work When the d...

Page 7: ...easy to use device that can output mA or volts control the systems connected to the output relays and give audible and visual warnings Developed considering the needs of the user the GA21 gas alarm d...

Page 8: ...count In case of connecting systems that draw excessive current it may cause unexpected possible malfunctions in the relay or components on the electronic board At the same time Low level adjustment c...

Page 9: ...2 10mA 0 2 10VDC 0 1 5VDC 10 C 50 C 85dB Audible lightand canbeviewedonthescreen 30 75 Turkish English blue white Keys and warning leds TECHNICAL FEATURES 1 2 3 4 5 6 7 8 DEFINITIONS Signal Selection...

Page 10: ...d the warranty period is 2 years The entire product including all its parts against failures that may arise from our production and assembly errors and or defective parts is within the scope of our co...

Page 11: ...the product that has been changed during the warranty period the purchased product TORK Industrial Automation Products San Trade Ltd St limited to the remaining warranty period provided by Free repai...

Page 12: ...End striyel Otomasyon r nleri San Tic Ltd ti 12 Before connecting and commissioning the GA21 gas alarm device the user should have information about the device in hand The table below gives informatio...

Page 13: ...as shut off valve connected to the device output will close it it will stop the gas passage When the power comes on the device will turn on and the device will continue to work normally The user must...

Page 14: ...etectors are connected The supply voltage of one of the GA21 gas alarm detectors is taken from pins 11 12 and the signal cable is connected to pin 15 The supply voltage of the other GA21 gas alarm det...

Page 15: ...hort circuit the GND pin on the signal output to the VIN pin or bridge it Connect the GND and S terminals directly to your system When the device is operated with a DC voltage output power supply the...

Page 16: ...www smstork com...

Page 17: ...SMS TORK End striyel Otomasyon r nleri San Tic Ltd ti NOTE...

Page 18: ...REA0150 31 01 2022 Rev 01 TR sms tork SMSTORK www smstork com KUL GA21 06 07 2022 Rev 04en P P erke li OSB Mah mes 2 Cad No5 Dilovas Kocaeli TURKEY Bostanc Yolu Cad Kuru Sok No 16 Y Dudullu 34776 mran...

Reviews: