2.  Start-up and Shut-down 

 

2. 1.   Start-up 

(1)  Before starting the initial operation after installation, observe the following check items and, if anything 

abnormal is found, take necessary corrective action in accordance with this Manual.

 

1) 

Are the pump and the suction pipe filled up with pumping liquid ?

 

2) 

Is the driver's rotating direction correct ? (Pump rotates clockwise viewing from the driver's side)

 

3) 

No abnormal in the direct coupling ?

 

4) 

No abnormal load to the pump by piping ?

 

5) 

Is the flushing pipe connected properly and the water flow rate proper ? 

6) 

Are the suction valve fully opened and the discharge valve fully closed ?

 

7)  Isn't the gland packing tightened irregularly or too excessively ? Also, isn't there any abnormal 

leakage from the gland packing ?

 

8) 

Can the pump be turned lightly by hand ? Isn't there any touch of contact in the pump ?

 

(2)  If nothing abnormal is found upon checking the above items, turns on the driver's start switch and off it 

immediately to check that the pump rotates smoothly and shuts down quietly.

 

(3)   If normal rotation of the pump is confirmed, gradually open the discharge valve up to the specific duty point, 

after the pump reached its specified running speed. When leakage from the gland is much, re-tighten the 

gland packing with equal torque for adjustment.

 

(4)   If the pump continues running with the discharge valve fully closed, the liquid temperature in the pump will 

rise, causing trouble of the pump. In such case, shut down the pump immediately without fail.

 

(5)   When starting the pump after long term shut-down, recheck the above check items (1), and (5) thru (8) to 

verify that the pump is abnormal-free.

 

 

2. 2.   Shut-down 

Follow the procedure given below for shutting down the pump. 

1)  Gradually close the discharge sluice valve up to full close position. However, it may be left as opened 

providing that a check valve is included in the discharge pipe and the back pressure is sufficient.

 

2)  Turn off the driver's stop switch. At the same time, check that the pump rotational speed decelerates 

smoothly and stops quietly.

 

3) 

Stop external flushing, if any.

 

4) 

Fully close the suction valve when the pump is kept as shutdown for long time.

 

5)  When there is a possibility of freezing in the pump, completely drain out the pumping liquid inside pump. 

(Complete drain of the liquid in the line is more safety) .

 

 

2. 3.   Maintenance 

2. 3. 1.   General 

The pump must run quietly and without abnormal vibration all the times. Therefore, carefully observe the follow-

ing check items while the pump is in running and, if anything abnormal is found, shut down the pump immediately and 

search the cause.

 

1)   Does  the  suction pressure fully satisfy the pump required NPSH (NPSH req.)  ? .... Read the suction line 

pressure gauge to check it.

 

2)    Is the specified discharge pressure satisfied ?

 

3)    Isn't the driver in overload running ?

 

Summary of Contents for MMO

Page 1: ...Operating Instruction MMO PT TORISHIMA GUNA INDONESIA High Pressure Centrifugal Pump...

Page 2: ...dling and operation faulty installation the use of unsuitable material faulty or unskilled piping etc 3 Pump damage is caused by natural disaster When repair is required it is recommended to repair th...

Page 3: ...baseplate is installed Therefore in this stage it would be sufficient only to keep each packer right horizontal 4 After complete cure up of the mortar with packer on temporarily install the common bas...

Page 4: ...l direction of the pump is arrow marked on the both suction and delivery casings Namely it is clockwise viewing from the motor side 4 After the above check connect the coupling halves 1 3 Connecting t...

Page 5: ...mp continues running with the discharge valve fully closed the liquid temperature in the pump will rise causing trouble of the pump In such case shut down the pump immediately without fail 5 When star...

Page 6: ...ngs 4610 or three packing rings plus one lantern ring 4580 2 3 2 Dimensions of stuffing box compartment and no of packing ring 3 Dismantling and Reassembling 3 1 General Before overhauling be sure to...

Page 7: ...p delivery side shaft protecting sleeve and gland in sequence 10 Unscrew off each tie bolt nut from the discharge side and dismantle the discharge casing and the last stage impeller 11 Dismantle the s...

Page 8: ...rrectly sized spacer ring 5 Follow the table below for the tie bolt tightening torque Unit kgf Pump Size 32 40 50 65 Tie bolt tightening torque 7 8 10 10 Table 2 Torque tightening tie bolt 6 After the...

Page 9: ...without fail Pump type No and size Manufacturing No These numbers are identified on the name plate attached to the pump Part name Part No Refer to attached List of Components Required quantity Materia...

Page 10: ...tion 1 The mechanical seal service life is significantly shortened by impurities if included therein Therefore clean the mechanical seal and the pump internals when reassembling and prevent invasion o...

Page 11: ...724 and spring 4770 are available for further re use unless they are flawed In addition if the wear degree of seat 4750 and washer 4720 is small these parts also are available for further re use by la...

Page 12: ...ft 6 Wipe off the sealing end face of the seat and the washer in finger for complete removal of dust After that joint the seal cover with gasket 4000 to the casing by tightening hexagon socket head bo...

Page 13: ...or at lower temperature than that specified in specification Where it is not impossible to keep specific gravity and temperature indicated in the specification but the discharge capacity to the allowa...

Page 14: ...imperfection or improper insertion of packing rings Re insert the packing rings 2 Damage of packing sleeve caused by over clamped or irregularly clamped gland Re polish or replace the sleeve After rep...