- 22 -
3.5. Sensor Setup
CATEGORY DEFAULT
ADJUSTMENT
SENSOR
NO.
1
Set the SENSOR Number.
[Left, Down] : Decrease Number
[Right, Up] : Increase Number
SENSOR
TYPE
NO
Select the SENSOR TYPE
[Up, Down, Left, Right] : Select NO or NC
CAMERA
LINK
Select the CAMERA that is to be connected to the SENSOR
[Left, Down, Right, Up] : Move between channels
[ENTER] : Toggle to Enable/Disable
ALARM
LINK
Select the ALARM OUTPUT that will be connected to the SENSOR
[Left, Down, Right, Up] : Move between channels
[ENTER] : Toggle to Enable/Disable
OPERATION
TIME
0~24
Set the OPERATION TIME for the selected sensor. (Start Hour ~ End Hour)
It will not activate if same time is set.
Range : 0~24(Hour), OFF
[Left, Right] : Move between Start ~ End
[Up, Down] : Increase/Decrease hour.
Number keys can also be used to change the hour.
OPERATION
MODE
SPOT
Set whether to show the camera view in full screen on the Spot monitor when
the sensor is triggered.
[NORMAL] : Disable
[SPOT] : Apply
If a sensor is linked to several channels, the channels will be displayed in the
multi-screen mode.
[Up, Down, Left, Right]: Move between NORMAL
Ù
SPOT
RECORDING
DWELL TIME
30
Set the time duration for which the camera will continue recording when the
sensor is triggered.
Input Range : 0~600(Second)
[Left, Down] : Decrease dwell time
[Right, Up] : Increase dwell time
Number keys can also be used to change the dwell time.
Configuration