GIRE-097-2-2
52
9. Element Replacement
Please at first lift "TMR090 Series" module out of the tank according to the lifting procedure
described in the former section and replace elements.
(1) Pull the permeate tubes, which are to be
replaced, out from element nozzles and manifold
nozzles.
* Pull out tubes straight up.
(2) Remove three element fixing brackets from
the element block according to the element fixing
bracket replacement procedure above.
(3) Pull up elements vertically one by one. Using the
element pullout tool (option tool) is recommended.
(4) Insert new elements into the element block along
the guides. Be careful not to damage the membrane
surface.
(5) Fit the three element fixing brackets
to the element block according to the element fixing
bracket replacement procedure described above.
(6) Fit tubes straight down to element nozzles and
manifold nozzles.
* Insert tubes deeply into the nozzles. Confirm that
all manifold nozzles are connected to element
nozzles with tubes.
Permeated water
nozzle
Tube
Element
Permeated water
manifold