21
V. Installation
1. Element into Rack
(1)Unpack the wooden box. Take the element out of plastic bag.
- Wear rubber gloves and safety glasses when you
unpack the element.
(2) Confirm the nozzle and the nut are not loose.
- Do not drop the element.
- Be careful not to install the element upside down.
Confirm the element is installed in the right direction.
- Do not allow the element to dry even for a few hours,
especially in summer.
- Do not freeze the element.
(3) Set the element vertically into a rack (see Fig. 6). Make sure that the element is
installed vertically. Please contact us if you need the detail information of the
rack.
(4) Connect a filtrate piping to a connection point of the element with a ferrule joint
(see Fig. 6).
- Keep the connection surface free of any dirt or oils.
- Do not over-tighten the clamp when using ferrule
joints (IDF/ISO Clamp Union Fittings 1.5s), or you
may damage the element.
(5) Immerse gradually the element rack in a submerged tank which filled raw water.
!