background image

-06-

-05-

INSTALLATION INSTRUCTIONS

1.

Check to see if Ambient Light Level is enabled by covering the lens by

hand.

2.

Check the wiring connections, especially Hot and Neutral wiring, and

make sure there is no loose wiring.

If within two(2) years from the date of purchase, this product fails due 
to a defect in material or workmanship, we will repair or exchange it, at

 

 its sole option free of charge. This warranty does not apply to: (a) damage 

to units caused by accident, dropping or abuse in handling, acts of God 

or any negligent use; (b) units which have been subject to un-authorized 
repair, opened, taken apart or otherwise modified; (c) unit not used in 
accordance with instruction; (d) damages exceeding the cost of the product;

(e) finish on any portion of the product, such as surface and weathering,

as this is considered normal wear and tear; (g) transit damage, initial

installation costs, removal costs, or rein-installation costs.

This warranty  service is available by returning the product with proof
of purchase, purchase date  and a description of the problem to the

dealer from whom the unit  was purchased.

MAY

.201

6

To operate properly, the Sensor Switch consumes power from the hot 
and Neutral. Therefore, a Secured Neutral Wiring is required. 

Initial run 

The Sensor Switch requires an initial run of one minute. During the 
initial run, the load may turn on and off several times. 
Do not adjust any settings it until the initial run completed.

1.

It can take up to one minute for initial run.

2.

Check the wiring connections, especially the

 

Neutral Wiring.

 

The load doesn't turn on when motion is detected 

1. Make sure the switch is in 'AUTO' mode

.(For TSOS5)

2.

There can be up to a 30 minutes time delay after the last motion

detected. To verify proper operation, turn the Time Delay Knob to 15s
(Test Mode), make sure there is no motion (no LED flashing), the
Load should turn Off in 15 seconds.

3.

Check if there is any significant heat source mounted within six feet (two

meters) that may cause false detection

,

 such as

 a

 high wattage light bulb,

portable heater

, or 

HAVC device.

4. Check the wiring connections, especially the Neutral wiring to the

sensor switch.

1.

Mask the Sensor Switch’s lens to eliminate unwanted coverage area.

2. Turn the Sensitivity Level knob to the left to avoid false alerts in

smaller rooms and if installed near the door way.

TROUBLESHOOTING

WARRANTY

The Load is out of control (frequently flashing)

The Load does not tu

rn

 

off

The Load turns On 

when there is no motion

 

-0

4

-

Reviews: