INSTALLATION INSTRUCTIONS 

Use the band switch located under the control panel cover to select 

the operation mode of the sensor switch. “OFF” mode powers off the 
entire  sensor.  “OCC”  mode  automatically  turns  the  load  on  and  off 
based  on  occupancy.  “VAC”  mode  requires  the  load  to  be  manually 
turned on and will automatically turn off the load based on occupancy. 
VAC mode can also be described as “Manual On Occupancy Mode”. 

Manual On/Off Button

 

By P

ressing

 the 

c

ontrol 

p

anel 

c

over, the Load can be turned On/Off 

under

 

OCC or VAC mode. (Illustrated 

in

 Figure 5) 

Turning On the Load under Occupancy Mode

Load 

will automatically turn on when

 occupancy 

is 

detected. 

Turning On the Load under Vacancy Mode

Press switch cover to manually turn on

 the 

l

oad. 

Automatic

ally

 Turning Off the Load 

Under either mode, the Sensor

 will

 keep the Load 

o

when

 no motion 

is detected 

for up to

 the set time delay

 before automatically turning off 

the load

Under VAC mode, the load will automatically turn back on if 

motion detected within the first 30 seconds.

-04-

Figure 5 

1.

It can take up to

 three

 minute for initial run

 to complete

.

2.

Check the wiring connections,  especially the 

Ground

 Wiring.

The Load does not t

urn

 

o

when motion is detected

1.

There can be up to a 30 minutes time delay after the last motion

detected. To verify proper operation, turn the Time Delay Knob to 15s
(Test Mode), make sure there is no motion (no LED flashing), 

and

the

 

Load should turn Off in  15 seconds.

2.

Check if there is any significant heat source mounted within six feet (two 

meters) that may cause false detection

,

 such as 

high wattage light

 

bulb,

portable heater

, or

 HAVC device.

3.

Check the wiring connections, especially the 

Ground

 wiring to the

sensor switch.

The Load turns 

o

when there is no motion

 

1.

S

witch from OCC to VAC mode

.

2.

Cover

 the Sensor Switch's lens to eliminate unwanted coverage area.

3.

Turn  the Sensitivity Level knob t

o the 

left to avoid false alert

s

 in 

smaller room

s

 and 

if installed 

near the door way.

If within two(2) years from the date of purchase, this product fails due to 

a defect in material or workmanship, we will repair or exchange it, at its 
sole option free of charge. This warranty does not apply to: (a) damage to 
units caused by accident, dropping or abuse in handling, acts of God or 
any negligent use; (b) units which have been subject to un-authorized 
repair,  opened, taken apart or otherwise  modified;  (c) unit not used in 
accordance with instruction; (d) damages exceeding the cost of the product; 
(e) finish on any portion of the product,  such as surface and weathering,
as this is considered normal wear and tear;  (g) transit damage, initial
installation costs, removal costs, or rein-installation costs.

This warranty  service is available by returning the product with proof of
purchase, purchase date  and a description of the problem to the
dealer from whom the unit  was purchased.

April,2016 

-06-

WARRANTY INFORMATION

To operate properly

, the Sensor Switch consume

s

 power from 

the 

hot 

and 

Ground

Therefore,  a 

Secured 

Ground

 Wiring is required.

 

Initial run

 

The Sensor Switch 

requires an

 

initial run

 of 

three 

minute. 

During the 

initial run,  the load 

may

 turn 

on and off

 several times. 

Do not adjust any setting until the initial run has completed.

 

The Load is out of control (frequently flashing) 

1.

Check to see if Ambient Light Level is enable

d

 by covering the lens

by hand.

2.

Check the wiring connections, especially 

Hot and Gr

ound

 wiring

, and 

make sure there is no loose wiring. 

2. Press and hold the Manual ON/OFF button (Figure 4) for 6 seconds
until the load turns on, release in the next 4 seconds.  The Load will
turn off for 10 seconds.
3. The  Load  will  turn  on  again  for  2  seconds  and  then  turn  off.  This
confirms that the present light level is now the set Ambient Light Level.
4.Set the Band Switch to OCC mode. The Load will now turn on only
when  the  present  light  level  is  below  the  Ambient  Light  Level  setting
and when motion is detected.

Back to factory default(daylight

). 

1. Set the Band Switch to VAC.
2. Press and hold the Manual ON/OFF button (Figure 4) until the Load

turns on, continue holding until the Load turns off. Release button.

3. Set the band Switch to OCC. The switch is now set to the factory

default mode.

The Load does not tu

rn

 Off

-0

5

-

Manually Turning Off the Load

You can manually turn off the load in OCC or VAC mode by pressing the 
switch cover. In OCC mode, the sensor will take about 5 minutes to 
reactivate and will not respond to motion during this time.

TROUBLESHOOTING