Masking (Laser beam shutter)
The RL-H2Sa features electronic beam “masking” to prevent the
beam from transmitting on one or multiple sides of the instrument.
This can be useful to eliminate duplicate laser beams on job sites
where more than one laser may be in use.
The beam plane is divided into four masking quadrants as indicated
on the masking display. The direction of the four masking quadrants
can be set as shown below.
1
Press the Mask key.
2
To change the masking direction mode, press the
Mask key again.
Each press toggles between the two masking
direction modes.
3
To mask a specific quadrant, press the arrow key
that corresponds to that quadrant.
Each press toggles between activating and
releasing the mask for that quadrant.
4
To mask additional quadrants, repeat step 3 with
the arrow key for that quadrant.
5
Press the Enter key to accept the masking set-
tings.