29
4) Sensitivity Level (LEVEL)
The sensitivity level allows the user to select the vibration level that is permitted during
automatic alignment or grade setting. Set a sensitivity level to suit the location where the
instrument is used such as places that undergo many vibrations, and also in consideration of
the operational precision.
Two sensitivity levels can be set: large and small vibrations.
Manual setting will stop the automatic alignment function.
Do not use the manual setting for sensitivity level except in special
circumstances. If the manual setting is selected, the automatic alignment function
will not operate, so the grading setting precision will not be assured at all. The
manual setting will also deactivate the settings for X- and Y-grades.
Large vibration
Small vibration
Manual